ID Description Savings Cost Payback Status
(1-18)
CO0162 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $480 $400 0.8 I
CO0162 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $1,460 $4,500 3.1 N
CO0162 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $580 $0 0.0 I
CO0162 INSTALL AUTOMATIC STACK DAMPER $800 $1,400 1.8 I
CO0162 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $920 $372 0.4 I
CO0162 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,510 $372 0.2 I
CO0162 INSTALL SET-BACK TIMERS $730 $800 1.1 N
CO0162 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $215 $250 1.2 I
CO0162 INSULATE BARE EQUIPMENT $1,520 $1,000 0.7 I
CO0026 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,177 $6,312 1.2 I
CO0026 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,652 $300 0.2 I
CO0026 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $49 $50 1.0 N
CO0026 USE DEMAND CONTROLLER OR LOAD SHEDDER $5,931 $3,500 0.6 N
CO0026 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $20,318 $25,000 1.2 I
CO0026 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $519 $3,500 6.7 N
CO0026 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $932 $200 0.2 N
CO0026 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $165 $200 1.2 I
CO0026 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $373 $2,000 5.4 N
(1-18)