WI0495 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $162,672 $360,000 2.2 N
WI0495 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,256 $32,760 2.3 I
WI0495 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,320 $360 0.1 I
WI0495 INSTALL AUTOMATIC STACK DAMPER $2,655 $3,400 1.3 N
WI0495 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,165 $0 0.0 I
WI0495 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,800 $1,280 0.7 N
WI0495 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $1,135 $1,500 1.3 I
WI0495 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $322 $150 0.5 N
WI0495 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $242 $200 0.8 I
WI0422 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $107,793 $715,000 6.6 N
WI0422 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $51,405 $31,028 0.6 N
WI0422 USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL $37,726 $40,000 1.1 N
WI0422 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,645 $21,689 3.3 I
WI0422 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $328 $0 0.0 N