ID Description Savings Cost Payback Impstatus
(1-25)Next 25 >
SD0402USE MULTIPLE SPEED MOTORS OR AFD FOR VARIABLE PUMP, BLOWER AND COMPRESSOR LOADS$125,747$39,4740.3N
SD0402USE MULTIPLE SPEED MOTORS OR AFD FOR VARIABLE PUMP, BLOWER AND COMPRESSOR LOADS$74,987$130,6351.7N
SD0402USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS$38,170$88,3002.3N
SD0402UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS$18,796$46,0942.5N
SD0402USE MULTIPLE SPEED MOTORS OR AFD FOR VARIABLE PUMP, BLOWER AND COMPRESSOR LOADS$15,282$11,1750.7N
SD0402USE MULTIPLE SPEED MOTORS OR AFD FOR VARIABLE PUMP, BLOWER AND COMPRESSOR LOADS$12,022$11,1750.9I
SD0402USE MULTIPLE SPEED MOTORS OR AFD FOR VARIABLE PUMP, BLOWER AND COMPRESSOR LOADS$11,958$11,0730.9N
SD0402ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES$7,363$9000.1I
SD0397USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM$51,686$51,2401.0N
SD0397USE MULTIPLE SPEED MOTORS OR AFD FOR VARIABLE PUMP, BLOWER AND COMPRESSOR LOADS$52,328$44,1750.8N
SD0397USE MULTIPLE SPEED MOTORS OR AFD FOR VARIABLE PUMP, BLOWER AND COMPRESSOR LOADS$3,149$18,1005.7N
SD0397USE ADJUSTABLE FREQUENCY DRIVE TO REPLACE MECHANICAL DRIVE$19,700$23,2501.2N
SD0397ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES$7,897$4200.1I
SD0397UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS$7,198$17,2142.4I
SD0397UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS$6,697$71,22410.6I
SD0397INSTALL SKYLIGHTS$4,924$13,3302.7N
SD0397USE MULTIPLE SPEED MOTORS OR AFD FOR VARIABLE PUMP, BLOWER AND COMPRESSOR LOADS$1,243$3,8253.1N
AS0433INSTALL EFFICIENT RECTIFIERS$540$15,00027.8n/a
AS0433REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED$7,142$7,5001.1n/a
AS0433USE SOLAR HEAT TO HEAT WATER$13,683$78,4005.7n/a
AS0433USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING$34,471$30,0000.9n/a
AS0432USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING$17,236$15,0000.9n/a
AS0432USE SOLAR HEAT TO HEAT WATER$13,683$78,4005.7n/a
AS0432SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING$9,888$3,0000.3n/a
AS0432INSTALL EFFICIENT RECTIFIERS$540$15,00027.8n/a