Assessment #MI0185


Assessment Date08/24/2009
SIC5181
SIC DescriptionBeer And Ale
NAICS424810
NAICS DecriptionBeer and Ale Merchant Wholesalers
Principal Productbeer
Sales$25,000,000
# of Employees395
Plant Area (Sq.Ft.)250,000
Annual Production100,000 Thousand Gallons
Production Hrs. Annual6,732
Location (StatePR
Fiscal Year (Budget Year)2009
Yearly Energy Cost$2,464,947

Current Energy Usage & Costs

Energy Sources Yearly Usage Yearly Cost Unit Price

Electricity

11,702,400 KWh $2,186,269 $0.187

- Demand Charge

32,936KW-Month/Year $269,848 $8.19

- Electricity Fees

- $8,830 -

Recommended Reduction in Usage & Costs

Energy Sources Yearly Usage Yearly Cost % Saved Unit Price

Electricity

727,110 KWh $53,567 2% $0.187

- Demand Charge

1,049 KW-Month/Year $7,472 3% $0.187

- Electricity Fees

0 KWh $0 0% $0.187

Recommendations

AR # Description ARC Code Status Cost Savings Payback
(Years)
1 view
details
USE FLUE GAS HEAT TO PREHEAT BOILER FEEDWATER 2.2412 $64,000 $123,100 0.5
Energy Type Usage Savings Cost Savings
#6 Fuel Oil 8,120 $123,100
2 view
details
ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO 2.1233 $1,750 $83,014 0.0
Energy Type Usage Savings Cost Savings
#6 Fuel Oil 5,403 $83,014
3 view
details
REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED 2.4231 $30 $37,375 0.0
Energy Type Usage Savings Cost Savings
Electrical Consumption 436,736 $30,572
Electrical Demand 644 $6,803
4 view
details
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES 2.4236 $1,210 $18,482 0.1
Energy Type Usage Savings Cost Savings
Electrical Consumption 265,042 $18,182
Electrical Demand 360 $300
5 view
details
REPAIR OR REPLACE STEAM TRAPS 2.2113 $1,700 $12,330 0.1
Energy Type Usage Savings Cost Savings
#6 Fuel Oil 813 $12,330
6 view
details
INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE 2.7496 $10,320 $5,182 2.0
Energy Type Usage Savings Cost Savings
Electrical Consumption 25,332 $4,813
Electrical Demand 45 $369