Assessment #IC0166


Assessment Date08/11/2009
SIC3841
SIC DescriptionSurgical And Medical Instruments
NAICS339112
NAICS DecriptionSurgical and Medical Instrument Manufacturing
Principal ProductMedical Instruments
Sales$31,000,000
# of Employees170
Plant Area (Sq.Ft.)67,000
Annual Production234,293 Pieces
Production Hrs. Annual4,216
Location (StateWI
Fiscal Year (Budget Year)2009
Yearly Energy Cost$184,594

Current Energy Usage & Costs

Energy Sources Yearly Usage Yearly Cost Unit Price

Electricity

2,130,240 KWh $112,624 $0.053

- Demand Charge

4,879KW-Month/Year $63,440 $13.00

- Electricity Fees

- $0 -

Natural Gas

764 MMBtu $8,530 $11.16

Recommended Reduction in Usage & Costs

Energy Sources Yearly Usage Yearly Cost % Saved Unit Price

Electricity

113,324 KWh $6,009 5% $0.053

- Demand Charge

429 KW-Month/Year $5,580 9% $0.053

Natural Gas

12 MMBtu $134 2% $11.16

Recommendations

AR # Description ARC Code Status Cost Savings Payback
(Years)
1 view
details
USE MORE EFFICIENT LIGHT SOURCE 2.7143 $10,994 $2,511 4.4
Energy Type Usage Savings Cost Savings
Electrical Consumption 18,298 $971
Electrical Demand 51 $663
Ancillary Material Cost 280 $877
2 view
details
USE MORE EFFICIENT LIGHT SOURCE 2.7143 $4,045 $3,135 1.3
Energy Type Usage Savings Cost Savings
Electrical Consumption 32,607 $1,728
Electrical Demand 113 $1,469
One-time Revenue or Avoided Cost 0 $334
Ancillary Material Cost 0 $-396
3 view
details
USE MORE EFFICIENT LIGHT SOURCE 2.7143 $136 $757 0.2
Energy Type Usage Savings Cost Savings
Electrical Consumption 3,373 $179
Electrical Demand 10 $130
One-time Revenue or Avoided Cost 0 $442
Ancillary Material Cost 0 $6
4 view
details
AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM 2.7228 $1,720 $2,442 0.7
Energy Type Usage Savings Cost Savings
Electrical Consumption 17,614 $934
Electrical Demand 116 $1,508
5 view
details
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES 2.4236 $345 $84 4.1
Energy Type Usage Savings Cost Savings
Electrical Consumption 1,574 $84
6 view
details
INSTALL TIMERS AND/OR THERMOSTATS 2.7261 $0 $134 0.0
Energy Type Usage Savings Cost Savings
Natural Gas 12 $134
7 view
details
USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER 2.2692 $16,200 $3,264 5.0
Energy Type Usage Savings Cost Savings
Electrical Consumption 36,258 $1,922
Electrical Demand 103 $1,342
8 view
details
CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES 2.6211 $0 $659 0.0
Energy Type Usage Savings Cost Savings
Electrical Consumption 3,600 $191
Electrical Demand 36 $468