Industrial Assessment Centers

Assessment #WV0320


Assessment Year 2005
SIC 3366
SIC Description Copper Foundries
NAICS 331525
NAICS Description Copper Foundries (except Die-Casting)
Principal Product Machine Tool Products
Sales $ 35,000,000
# of Employees 165
Plant Area (Sq.Ft.) 104,000
Annual Production 10,400,000 Pieces
Production Hrs. Annual 6,656
Location (State) OH
Yearly Energy Cost $ 196,950

Current Energy Usage & Costs

Energy Sources Yearly Usage Yearly Cost Unit Price

Electricity

1,807,200 kWh $ 144,112 $ 0.080 /kWh

- Demand Charge

4,966 kW $ 33,233 $ 6.69 /kW

- Electricity Fees

- $ 593 -

Natural Gas

1,735 MMBtu $ 19,012 $ 10.96 /MMBtu

TOTAL ENERGY

20,258 MMBtu $ 196,950 $ 9.72 /MMBtu

Recommended Reduction in Usage & Costs

Recommended
Implemented
Energy Sources Yearly Savings Yearly Cost % Saved Unit Price

Electricity

433,960 kWh
361,695 kWh
$ 34,590
$ 28,839
24.00 %
20.01 %
$ 0.080 /kWh

- Demand Charge

861 kW
715 kW
$ 5,758
$ 4,782
17.33 %
14.39 %
$ 6.69 /kW

- Electricity Fees

- $ 0
$ 0
0.00 %
0.00 %
-

Natural Gas

580 MMBtu
158 MMBtu
$ 6,357
$ 1,732
33.44 %
9.11 %
$ 10.96 /MMBtu

TOTAL ENERGY

5,028 MMBtu
3,865 MMBtu
$ 46,705
$ 35,353
23.71 %
17.95 %
$ 9.72 /MMBtu

Recommendations

AR # Description ARC Code Status Cost Savings Payback
(Years)
01 view
details
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS 2.7142 I $ 30,000 $ 15,626 1.92
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

170,287 kWh $ 13,572 $ 0.080 /kWh

- Demand Charge

307 kW $ 2,054 $ 6.69 /kW

TOTAL ENERGY

1,745 MMBtu $ 15,626 -
02 view
details
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS 2.7142 I $ 5,805 $ 4,978 1.17
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

54,151 kWh $ 4,322 $ 0.080 /kWh

- Demand Charge

98 kW $ 656 $ 6.69 /kW

TOTAL ENERGY

555 MMBtu $ 4,978 -
03 view
details
BURN WASTE OIL FOR HEAT 3.6124 N $ 4,000 $ 4,770 0.84
Energy Sources Yearly Reduction Yearly Savings Unit Price

Natural Gas

333 MMBtu $ 3,650 $ 10.96 /MMBtu

TOTAL ENERGY

333 MMBtu $ 3,650 -

Other Liquid (non-haz)

2,000 Gal $ 1,120 $ 0 /Gal

TOTAL WASTE

- $ 1,120 -
04 view
details
INSTALL OCCUPANCY SENSORS 2.7135 I $ 4,750 $ 4,359 1.09
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

47,517 kWh $ 3,784 $ 0.080 /kWh

- Demand Charge

86 kW $ 575 $ 6.69 /kW

TOTAL ENERGY

487 MMBtu $ 4,359 -
05 view
details
USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING 2.2614 I $ 2,700 $ 4,094 0.66
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

39,848 kWh $ 3,177 $ 0.080 /kWh

- Demand Charge

137 kW $ 917 $ 6.69 /kW

TOTAL ENERGY

408 MMBtu $ 4,094 -
06 view
details
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS 2.7142 N $ 0 $ 3,232 0.00
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

35,144 kWh $ 2,804 $ 0.080 /kWh

- Demand Charge

64 kW $ 428 $ 6.69 /kW

TOTAL ENERGY

360 MMBtu $ 3,232 -
07 view
details
USE COMPRESSOR AIR FILTERS 2.4227 N $ 800 $ 2,183 0.37
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

23,780 kWh $ 1,896 $ 0.080 /kWh

- Demand Charge

43 kW $ 287 $ 6.69 /kW

TOTAL ENERGY

244 MMBtu $ 2,183 -
08 view
details
RECOVER HEAT FROM AIR COMPRESSOR 2.2434 I $ 1,645 $ 1,732 0.95
Energy Sources Yearly Reduction Yearly Savings Unit Price

Natural Gas

158 MMBtu $ 1,732 $ 10.96 /MMBtu

TOTAL ENERGY

158 MMBtu $ 1,732 -
09 view
details
DEVELOP A REPAIR/REPLACE POLICY 2.4151 I $ 213 $ 1,621 0.13
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

24,026 kWh $ 1,929 $ 0.080 /kWh

- Demand Charge

44 kW $ 292 $ 6.69 /kW

TOTAL ENERGY

246 MMBtu $ 2,221 -

Personnel Changes

- $ -600 -

TOTAL PRODUCTON

- $ -600 -
10 view
details
PREHEAT COMBUSTION AIR WITH WASTE HEAT 2.2442 N $ 955 $ 975 0.98
Energy Sources Yearly Reduction Yearly Savings Unit Price

Natural Gas

89 MMBtu $ 975 $ 10.96 /MMBtu

TOTAL ENERGY

89 MMBtu $ 975 -
11 view
details
USE MORE EFFICIENT LIGHT SOURCE 2.7143 I $ 667 $ 728 0.92
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

8,322 kWh $ 654 $ 0.080 /kWh

- Demand Charge

11 kW $ 74 $ 6.69 /kW

TOTAL ENERGY

85 MMBtu $ 728 -
12 view
details
INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS 2.4221 N $ 400 $ 487 0.82
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

5,290 kWh $ 420 $ 0.080 /kWh

- Demand Charge

10 kW $ 67 $ 6.69 /kW

TOTAL ENERGY

54 MMBtu $ 487 -
13 view
details
UTILIZE A LESS EXPENSIVE COOLING METHOD 2.2628 N $ 488 $ 474 1.03
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

4,242 kWh $ 327 $ 0.080 /kWh

- Demand Charge

22 kW $ 147 $ 6.69 /kW

TOTAL ENERGY

43 MMBtu $ 474 -
14 view
details
REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED 2.4231 I $ 430 $ 457 0.94
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

4,982 kWh $ 397 $ 0.080 /kWh

- Demand Charge

9 kW $ 60 $ 6.69 /kW

TOTAL ENERGY

51 MMBtu $ 457 -
15 view
details
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES 2.4236 I $ 80 $ 438 0.18
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

12,562 kWh $ 1,004 $ 0.080 /kWh

- Demand Charge

23 kW $ 154 $ 6.69 /kW

TOTAL ENERGY

129 MMBtu $ 1,158 -

Personnel Changes

- $ -600 -

Primary Raw Material

- $ -120 -

TOTAL PRODUCTON

- $ -720 -
16 view
details
REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY 2.1135 N $ 26 $ 351 0.07
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

3,809 kWh $ 304 $ 0.080 /kWh

- Demand Charge

7 kW $ 47 $ 6.69 /kW

TOTAL ENERGY

39 MMBtu $ 351 -