Industrial Assessment Centers
Assessment #WI0518
| Assessment Year | 2006 |
|---|---|
| SIC | 2752 |
| SIC Description | Commercial Printing, Lithographic |
| NAICS | 0 |
| NAICS Description | |
| Principal Product | printing books |
| Sales | $ 40,000,000 |
| # of Employees | 327 |
| Plant Area (Sq.Ft.) | 240,000 |
| Annual Production | 40,000,000 Pounds |
| Production Hrs. Annual | 6,000 |
| Location (State) | WI |
| Yearly Energy Cost | $ 586,826 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
79,608,000 kWh | $ 291,291 | $ 0.004 /kWh |
- Demand Charge |
22,520 kW | $ 186,487 | $ 8.28 /kW |
- Electricity Fees |
- | $ 0 | - |
Natural Gas |
9,937 MMBtu | $ 109,048 | $ 10.97 /MMBtu |
TOTAL ENERGY |
825,919 MMBtu | $ 586,826 | $ 0.71 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
299,031 kWh 83,546 kWh |
$ 11,282 $ 3,207 |
3.87 % 1.10 % |
$ 0.004 /kWh |
- Demand Charge |
1,576 kW 950 kW |
$ 14,042 $ 7,592 |
7.53 % 4.07 % |
$ 8.28 /kW |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
1,354 MMBtu 0 MMBtu |
$ 14,585 $ 0 |
13.37 % 0.00 % |
$ 10.97 /MMBtu |
TOTAL ENERGY |
4,420 MMBtu 857 MMBtu |
$ 39,909 $ 10,799 |
6.80 % 1.84 % |
$ 0.71 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
IMPROVE SPACE COMFORT CONDITIONING | 4.4240 | I | $ 4,975 | $ 39,412 | 0.13 | ||||||||||||||||
|
|||||||||||||||||||||||
| 02 | view details |
USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT COMBUSTION AIR | 2.2411 | N | $ 11,000 | $ 14,585 | 0.75 | ||||||||||||||||
|
|||||||||||||||||||||||
| 03 | view details |
RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | 2.3131 | I | $ 0 | $ 5,873 | 0.00 | ||||||||||||||||
|
|||||||||||||||||||||||
| 04 | view details |
INSTALL SET-BACK TIMERS | 2.6232 | N | $ 1,400 | $ 4,978 | 0.28 | ||||||||||||||||
|
|||||||||||||||||||||||
| 05 | view details |
REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | 2.2622 | N | $ 7,000 | $ 4,862 | 1.44 | ||||||||||||||||
|
|||||||||||||||||||||||
| 06 | view details |
USE MULTIPLE SPEED MOTORS OR AFD FOR VARIABLE PUMP, BLOWER AND COMPRESSOR LOADS | 2.4141 | N | $ 1,630 | $ 3,802 | 0.43 | ||||||||||||||||
|
|||||||||||||||||||||||
| 07 | view details |
INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | 2.4221 | I | $ 2,560 | $ 1,994 | 1.28 | ||||||||||||||||
|
|||||||||||||||||||||||
| 08 | view details |
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | 2.4236 | I | $ 0 | $ 1,722 | 0.00 | ||||||||||||||||
|
|||||||||||||||||||||||
| 09 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 778 | $ 1,210 | 0.64 | ||||||||||||||||
|
|||||||||||||||||||||||
| 10 | view details |
MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | 2.6127 | N | $ 0 | $ 883 | 0.00 | ||||||||||||||||
|
|||||||||||||||||||||||