Industrial Assessment Centers

Assessment #UW0016


Assessment Year 2008
SIC 2099
SIC Description Food Preparations, Nec
NAICS 311999
NAICS Description All Other Miscellaneous Food Manufacturing
Principal Product Tofu and Tofu Products
Sales $ 2,000,000
# of Employees 22
Plant Area (Sq.Ft.) 10,000
Annual Production 540,000 Pounds
Production Hrs. Annual 3,510
Location (State) HI
Yearly Energy Cost $ 98,896

Current Energy Usage & Costs

Energy Sources Yearly Usage Yearly Cost Unit Price

Electricity

73,415 kWh $ 14,635 $ 0.199 /kWh

- Demand Charge

300 kW $ 1,718 $ 5.73 /kW

- Electricity Fees

- $ 0 -

Natural Gas

2,419 MMBtu $ 82,543 $ 34.12 /MMBtu

TOTAL ENERGY

3,172 MMBtu $ 98,896 $ 31.18 /MMBtu

Water Disposal

10,448,854 Gal $ 62,188 $ 0 /Gal

Recommended Reduction in Usage & Costs

Recommended
Implemented
Energy Sources Yearly Savings Yearly Cost % Saved Unit Price

Electricity

28,510 kWh
24,255 kWh
$ 5,416
$ 4,608
37.01 %
31.49 %
$ 0.199 /kWh

- Demand Charge

18 kW
3 kW
$ 101
$ 17
5.88 %
0.99 %
$ 5.73 /kW

- Electricity Fees

- $ 0
$ 0
0.00 %
0.00 %
-

Natural Gas

2,249 MMBtu
548 MMBtu
$ 52,128
$ 36,638
63.15 %
44.39 %
$ 34.12 /MMBtu

TOTAL ENERGY

2,542 MMBtu
797 MMBtu
$ 57,645
$ 41,263
58.29 %
41.72 %
$ 31.18 /MMBtu

Water Disposal

631,000 Gal
0 Gal
$ 5,510
$ 0
8.86 %
0.00 %
$ 0 /Gal

Recommendations

AR # Description ARC Code Status Cost Savings Payback
(Years)
01 view
details
CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE 2.8114 I $ 0 $ 29,638 0.00
Energy Sources Yearly Reduction Yearly Savings Unit Price

Natural Gas

0 MMBtu $ 29,638 $ 34.12 /MMBtu

TOTAL ENERGY

0 MMBtu $ 29,638 -
02 view
details
REPLACE BOILER 2.1224 N $ 20,000 $ 10,000 2.00
Energy Sources Yearly Reduction Yearly Savings Unit Price

Natural Gas

1,001 MMBtu $ 10,000 $ 34.12 /MMBtu

TOTAL ENERGY

1,001 MMBtu $ 10,000 -
03 view
details
REPAIR OR REPLACE STEAM TRAPS 2.2113 N $ 5,600 $ 5,490 1.02
Energy Sources Yearly Reduction Yearly Savings Unit Price

Natural Gas

700 MMBtu $ 5,490 $ 34.12 /MMBtu

TOTAL ENERGY

700 MMBtu $ 5,490 -
04 view
details
INSULATE BARE EQUIPMENT 2.2511 I $ 500 $ 7,000 0.07
Energy Sources Yearly Reduction Yearly Savings Unit Price

Natural Gas

548 MMBtu $ 7,000 $ 34.12 /MMBtu

TOTAL ENERGY

548 MMBtu $ 7,000 -
05 view
details
REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS 2.2523 I $ 8,550 $ 4,625 1.85
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

24,255 kWh $ 4,608 $ 0.199 /kWh

- Demand Charge

3 kW $ 17 $ 5.73 /kW

TOTAL ENERGY

249 MMBtu $ 4,625 -
06 view
details
USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE 3.4156 N $ 10 $ 5,510 0.00
Energy Sources Yearly Reduction Yearly Savings Unit Price

Water Disposal

631,000 Gal $ 5,510 $ 0 /Gal

TOTAL WASTE

- $ 5,510 -
07 view
details
REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED 2.4231 N $ 0 $ 892 0.00
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

4,255 kWh $ 808 $ 0.199 /kWh

- Demand Charge

15 kW $ 84 $ 5.73 /kW

TOTAL ENERGY

44 MMBtu $ 892 -