Industrial Assessment Centers
Assessment #UF0440
| Assessment Year | 2011 |
|---|---|
| SIC | 2086 |
| SIC Description | Bottled And Canned Soft Drinks |
| NAICS | 312111 |
| NAICS Description | Soft Drink Manufacturing |
| Principal Product | soda, soft drinks |
| Sales | $ 11,000,000 |
| # of Employees | 90 |
| Plant Area (Sq.Ft.) | 192,000 |
| Annual Production | 11,000,000 Not Available |
| Production Hrs. Annual | 5,460 |
| Location (State) | FL |
| Yearly Energy Cost | $ 822,943 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
7,574,423 kWh | $ 526,621 | $ 0.070 /kWh |
- Demand Charge |
17,071 kW | $ 192,763 | $ 11.29 /kW |
- Electricity Fees |
- | $ 0 | - |
Natural Gas |
16,623 MMBtu | $ 103,559 | $ 6.23 /MMBtu |
TOTAL ENERGY |
94,262 MMBtu | $ 822,943 | $ 8.73 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
1,268,257 kWh 0 kWh |
$ 102,082 $ 0 |
19.38 % 0.00 % |
$ 0.070 /kWh |
- Demand Charge |
156 kW 0 kW |
$ 1,761 $ 0 |
0.91 % 0.00 % |
$ 11.29 /kW |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
557 MMBtu 0 MMBtu |
$ 3,881 $ 0 |
3.75 % 0.00 % |
$ 6.23 /MMBtu |
TOTAL ENERGY |
13,557 MMBtu 0 MMBtu |
$ 107,724 $ 0 |
13.09 % 0.00 % |
$ 8.73 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | 2.7226 | N | $ 25,340 | $ 43,145 | 0.59 | ||||||||||||||||
|
|||||||||||||||||||||||
| 02 | view details |
CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | 2.7425 | N | $ 5,896 | $ 3,404 | 1.73 | ||||||||||||||||
|
|||||||||||||||||||||||
| 03 | view details |
CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | 2.6211 | N | $ 1,818 | $ 1,173 | 1.55 | ||||||||||||||||
|
|||||||||||||||||||||||
| 04 | view details |
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | 2.4236 | N | $ 3,778 | $ 8,370 | 0.45 | ||||||||||||||||
|
|||||||||||||||||||||||
| 05 | view details |
UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | 2.6231 | N | $ 12,180 | $ 28,580 | 0.43 | ||||||||||||||||
|
|||||||||||||||||||||||
| 06 | view details |
REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | 2.1131 | N | $ 244 | $ 136 | 1.79 | ||||||||||||||||
|
|||||||||||||||||||||||
| 07 | view details |
INSTALL TURBULATORS | 2.1222 | N | $ 3,750 | $ 3,745 | 1.00 | ||||||||||||||||
|
|||||||||||||||||||||||
| 08 | view details |
USE MORE EFFICIENT LIGHT SOURCE | 2.7143 | N | $ 9,387 | $ 14,493 | 0.65 | ||||||||||||||||
|
|||||||||||||||||||||||
| 09 | view details |
INSTALL OCCUPANCY SENSORS | 2.7135 | N | $ 243 | $ 2,620 | 0.09 | ||||||||||||||||
|
|||||||||||||||||||||||
| 10 | view details |
KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | 2.7442 | N | $ 0 | $ 635 | 0.00 | ||||||||||||||||
|
|||||||||||||||||||||||
| 11 | view details |
AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | 2.7228 | N | $ 840 | $ 1,423 | 0.59 | ||||||||||||||||
|
|||||||||||||||||||||||