Industrial Assessment Centers
Assessment #UF0390
| Assessment Year | 2006 |
|---|---|
| SIC | 3511 |
| SIC Description | Turbines And Turbine Generator Sets |
| NAICS | 333611 |
| NAICS Description | Turbine and Turbine Generator Set Units Manufacturing |
| Principal Product | Wind turbines |
| Sales | $ 0 |
| # of Employees | 106 |
| Plant Area (Sq.Ft.) | 394,397 |
| Annual Production | 1,000 Pieces |
| Production Hrs. Annual | 7,072 |
| Location (State) | FL |
| Yearly Energy Cost | $ 668,822 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
11,571,813 kWh | $ 468,104 | $ 0.040 /kWh |
- Demand Charge |
19,831 kW | $ 200,718 | $ 10.12 /kW |
- Electricity Fees |
- | $ 0 | - |
TOTAL ENERGY |
118,611 MMBtu | $ 668,822 | $ 5.64 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
6,552,879 kWh 0 kWh |
$ 371,251 $ 0 |
79.31 % 0.00 % |
$ 0.040 /kWh |
- Demand Charge |
427 kW 0 kW |
$ 4,314 $ 0 |
2.15 % 0.00 % |
$ 10.12 /kW |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
TOTAL ENERGY |
67,166 MMBtu 0 MMBtu |
$ 375,565 $ 0 |
56.15 % 0.00 % |
$ 5.64 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | N | $ 619,757 | $ 148,376 | 4.18 | ||||||||||||||||
|
|||||||||||||||||||||||
| 02 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | N | $ 8,763 | $ 5,981 | 1.47 | ||||||||||||||||
|
|||||||||||||||||||||||
| 03 | view details |
INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | 2.7447 | N | $ 39,000 | $ 87,992 | 0.44 | ||||||||||||||||
|
|||||||||||||||||||||||
| 04 | view details |
AIR CONDITION ONLY SPACE IN USE | 2.7222 | N | $ 1,080 | $ 41,661 | 0.03 | ||||||||||||||||
|
|||||||||||||||||||||||
| 05 | view details |
UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | 2.4111 | N | $ 0 | $ 5,722 | 0.00 | ||||||||||||||||
|
|||||||||||||||||||||||
| 06 | view details |
USE MULTIPLE SPEED MOTORS OR AFD FOR VARIABLE PUMP, BLOWER AND COMPRESSOR LOADS | 2.4141 | N | $ 31,040 | $ 11,951 | 2.60 | ||||||||||||||||
|
|||||||||||||||||||||||
| 07 | view details |
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | 2.4236 | N | $ 513 | $ 29,826 | 0.02 | ||||||||||||||||
|
|||||||||||||||||||||||
| 08 | view details |
USE PHOTOCELL CONTROLS | 2.7134 | N | $ 306 | $ 909 | 0.34 | ||||||||||||||||
|
|||||||||||||||||||||||
| 09 | view details |
USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | 2.7226 | N | $ 20,000 | $ 27,903 | 0.72 | ||||||||||||||||
|
|||||||||||||||||||||||
| 10 | view details |
INSTALL OCCUPANCY SENSORS | 2.7135 | N | $ 347 | $ 437 | 0.79 | ||||||||||||||||
|
|||||||||||||||||||||||
| 11 | view details |
REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | 2.7111 | N | $ 36,122 | $ 10,152 | 3.56 | ||||||||||||||||
|
|||||||||||||||||||||||
| 12 | view details |
REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | 2.7111 | N | $ 1,610 | $ 4,655 | 0.35 | ||||||||||||||||
|
|||||||||||||||||||||||
| 13 | view details |
INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | 3.6193 | N | $ 4,996 | $ 979 | 5.10 | ||||||||||||||||
|
|||||||||||||||||||||||
| 14 | view details |
INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | 3.6193 | N | $ 8,400 | $ 118,800 | 0.07 | ||||||||||||||||
|
|||||||||||||||||||||||