Industrial Assessment Centers
Assessment #UF0292
| Assessment Year | 2002 |
|---|---|
| SIC | 2521 |
| SIC Description | Wood Office Furniture |
| NAICS | |
| NAICS Description | |
| Principal Product | Restaurant Furniture |
| Sales | $ 9,000,000 |
| # of Employees | 88 |
| Plant Area (Sq.Ft.) | 60,000 |
| Annual Production | 200 Pieces |
| Production Hrs. Annual | 2,730 |
| Location (State) | FL |
| Yearly Energy Cost | $ 65,779 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
757,837 kWh | $ 45,714 | $ 0.060 /kWh |
- Demand Charge |
2,748 kW | $ 20,065 | $ 7.30 /kW |
- Electricity Fees |
- | $ 0 | - |
TOTAL ENERGY |
7,768 MMBtu | $ 65,779 | $ 8.47 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
190,855 kWh 190,855 kWh |
$ 15,809 $ 15,809 |
34.58 % 34.58 % |
$ 0.060 /kWh |
- Demand Charge |
69 kW 69 kW |
$ 6,039 $ 6,039 |
30.10 % 30.10 % |
$ 7.30 /kW |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
TOTAL ENERGY |
1,955 MMBtu 1,955 MMBtu |
$ 21,848 $ 21,848 |
33.21 % 33.21 % |
$ 8.47 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | 2.4133 | I | $ 24,472 | $ 6,946 | 3.52 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 02 | view details |
UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | 2.7121 | I | $ 6,547 | $ 7,392 | 0.89 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 03 | view details |
APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | 2.8121 | I | $ 50 | $ 4,788 | 0.01 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 04 | view details |
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | 2.4236 | I | $ 350 | $ 1,347 | 0.26 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 05 | view details |
REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | 2.4231 | I | $ 0 | $ 587 | 0.00 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 06 | view details |
CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | 3.1191 | I | $ 4,000 | $ 46,032 | 0.09 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 07 | view details |
CONTRACT A WOOD PALLET RECYCLING COMPANY | 3.5316 | I | $ 0 | $ 468 | 0.00 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 08 | view details |
INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM | 4.4480 | N | $ 876 | $ 2,808 | 0.31 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 09 | view details |
CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | 4.4320 | I | $ 24,938 | $ 11,250 | 2.22 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 10 | view details |
USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | 2.7492 | I | $ 39,000 | $ 140,438 | 0.28 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||