Industrial Assessment Centers
Assessment #UF0259
| Assessment Year | 2000 |
|---|---|
| SIC | 3824 |
| SIC Description | Fluid Meters And Counting Devices |
| NAICS | |
| NAICS Description | |
| Principal Product | Water Meters |
| Sales | $ 42,000,000 |
| # of Employees | 180 |
| Plant Area (Sq.Ft.) | 90,000 |
| Annual Production | 600,000 Pieces |
| Production Hrs. Annual | 6,240 |
| Location (State) | FL |
| Yearly Energy Cost | $ 188,864 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
2,373,095 kWh | $ 147,178 | $ 0.062 /kWh |
- Demand Charge |
7,006 kW | $ 41,686 | $ 5.95 /kW |
- Electricity Fees |
- | $ 0 | - |
TOTAL ENERGY |
24,324 MMBtu | $ 188,864 | $ 7.76 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
259,085 kWh 179,952 kWh |
$ 18,438 $ 12,361 |
12.53 % 8.40 % |
$ 0.062 /kWh |
- Demand Charge |
19 kW 19 kW |
$ 1,362 $ 1,362 |
3.27 % 3.27 % |
$ 5.95 /kW |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
TOTAL ENERGY |
2,654 MMBtu 1,843 MMBtu |
$ 19,800 $ 13,723 |
10.48 % 7.27 % |
$ 7.76 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 2,831 | $ 5,865 | 0.48 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 02 | view details |
INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | 2.7491 | N | $ 12,014 | $ 5,242 | 2.29 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 03 | view details |
USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | 2.4133 | I | $ 7,400 | $ 1,732 | 4.27 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 04 | view details |
APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | 2.8121 | I | $ 50 | $ 10,323 | 0.00 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 05 | view details |
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | 2.4236 | I | $ 460 | $ 2,597 | 0.18 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 06 | view details |
REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | 2.4231 | I | $ 0 | $ 2,740 | 0.00 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 07 | view details |
INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | 2.4221 | N | $ 1,500 | $ 835 | 1.80 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 08 | view details |
INSTALL OCCUPANCY SENSORS | 2.7135 | I | $ 834 | $ 481 | 1.73 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 09 | view details |
USE MORE EFFICIENT LIGHT SOURCE | 2.7143 | I | $ 600 | $ 704 | 0.85 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 10 | view details |
METER WASTE WATER | 3.4155 | I | $ 1,500 | $ 2,940 | 0.51 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 11 | view details |
BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | 4.6110 | N | $ 3,721 | $ 1,874 | 1.99 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 12 | view details |
INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | 4.7110 | N | $ 84,000 | $ 67,200 | 1.25 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||