Industrial Assessment Centers
Assessment #TN0436
| Assessment Year | 1991 |
|---|---|
| SIC | 3995 |
| SIC Description | Burial Caskets |
| NAICS | |
| NAICS Description | |
| Principal Product | HARDWOOD PARTS |
| Sales | $ 6,000,000 |
| # of Employees | 200 |
| Plant Area (Sq.Ft.) | 0 |
| Annual Production | 1,300 Thousand Feet |
| Production Hrs. Annual | 2,250 |
| Location (State) | TN |
| Yearly Energy Cost | $ 294,267 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
3,220,985 kWh | $ 222,550 | $ 0.069 /kWh |
- Electricity Fees |
- | $ 0 | - |
Natural Gas |
8,761 MMBtu | $ 37,877 | $ 4.32 /MMBtu |
Fuel Oil #2 |
5,040 MMBtu | $ 24,840 | $ 4.93 /MMBtu |
Wood |
185,760 MMBtu | $ 9,000 | $ 0.05 /MMBtu |
TOTAL ENERGY |
232,576 MMBtu | $ 294,267 | $ 1.27 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
251,466 kWh 251,466 kWh |
$ 23,097 $ 23,097 |
10.38 % 10.38 % |
$ 0.069 /kWh |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
8,274 MMBtu 8,274 MMBtu |
$ 35,580 $ 35,580 |
93.94 % 93.94 % |
$ 4.32 /MMBtu |
Fuel Oil #2 |
0 MMBtu 0 MMBtu |
$ 0 $ 0 |
0.00 % 0.00 % |
$ 4.93 /MMBtu |
Wood |
0 MMBtu 0 MMBtu |
$ 0 $ 0 |
0.00 % 0.00 % |
$ 0.05 /MMBtu |
TOTAL ENERGY |
10,851 MMBtu 10,851 MMBtu |
$ 58,677 $ 58,677 |
19.94 % 19.94 % |
$ 1.27 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
INSULATE STEAM / HOT WATER LINES | 2.2131 | I | $ 1,204 | $ 26,217 | 0.05 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 02 | view details |
REPAIR LEAKS IN LINES AND VALVES | 2.2133 | I | $ 500 | $ 9,331 | 0.05 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 03 | view details |
UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | 2.6231 | I | $ 12,057 | $ 6,936 | 1.74 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 04 | view details |
UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | 2.4111 | I | $ 0 | $ 5,440 | 0.00 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 05 | view details |
KEEP LAMPS AND REFLECTORS CLEAN | 2.7123 | I | $ 0 | $ 3,626 | 0.00 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 06 | view details |
TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | 2.6212 | I | $ 19,100 | $ 6,646 | 2.87 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 07 | view details |
INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | 2.7212 | I | $ 0 | $ 487 | 0.00 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 08 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 392 | $ 162 | 2.42 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||