Industrial Assessment Centers
Assessment #TN0402
| Assessment Year | 1990 |
|---|---|
| SIC | 3861 |
| SIC Description | Photographic Equipment And Supplies |
| NAICS | |
| NAICS Description | |
| Principal Product | PHOTO ENLARGERS |
| Sales | $ 4,500,000 |
| # of Employees | 50 |
| Plant Area (Sq.Ft.) | 0 |
| Annual Production | 150 Pieces |
| Production Hrs. Annual | 2,444 |
| Location (State) | TN |
| Yearly Energy Cost | $ 30,487 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
424,971 kWh | $ 27,594 | $ 0.065 /kWh |
- Electricity Fees |
- | $ 0 | - |
Natural Gas |
524 MMBtu | $ 2,893 | $ 5.52 /MMBtu |
TOTAL ENERGY |
4,880 MMBtu | $ 30,487 | $ 6.25 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
174,676 kWh 161,781 kWh |
$ 11,347 $ 10,510 |
41.12 % 38.09 % |
$ 0.065 /kWh |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
112 MMBtu 112 MMBtu |
$ 627 $ 627 |
21.67 % 21.67 % |
$ 5.52 /MMBtu |
TOTAL ENERGY |
1,901 MMBtu 1,769 MMBtu |
$ 11,974 $ 11,137 |
39.28 % 36.53 % |
$ 6.25 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
KEEP LAMPS AND REFLECTORS CLEAN | 2.7123 | I | $ 11,116 | $ 4,123 | 2.70 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 02 | view details |
INSTALL TIMERS AND/OR THERMOSTATS | 2.7261 | I | $ 4,140 | $ 2,474 | 1.67 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 03 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 960 | $ 1,428 | 0.67 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 04 | view details |
REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | 2.7111 | I | $ 0 | $ 1,440 | 0.00 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 05 | view details |
USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | 2.7226 | I | $ 0 | $ 925 | 0.00 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 06 | view details |
USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | 2.7133 | I | $ 500 | $ 880 | 0.57 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 07 | view details |
MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | 2.6242 | N | $ 660 | $ 780 | 0.85 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 08 | view details |
DISCONNECT BALLASTS | 2.7122 | I | $ 0 | $ 96 | 0.00 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 09 | view details |
IMPROVE LUBRICATION PRACTICES | 2.4312 | N | $ 30 | $ 57 | 0.53 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||