Industrial Assessment Centers
Assessment #SF0353
| Assessment Year | 2008 |
|---|---|
| SIC | 2084 |
| SIC Description | Wines, Brandy, And Brandy Spirits |
| NAICS | 312130 |
| NAICS Description | Wineries |
| Principal Product | Bottled wine |
| Sales | $ 31,000,000 |
| # of Employees | 77 |
| Plant Area (Sq.Ft.) | 120,000 |
| Annual Production | 300,000 Not Available |
| Production Hrs. Annual | 4,368 |
| Location (State) | CA |
| Yearly Energy Cost | $ 317,427 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
2,768,977 kWh | $ 241,017 | $ 0.087 /kWh |
- Demand Charge |
7,499 kW | $ 85 | $ 0.01 /kW |
- Electricity Fees |
- | $ 11,841 | - |
Natural Gas |
5,854 MMBtu | $ 64,484 | $ 11.02 /MMBtu |
TOTAL ENERGY |
34,236 MMBtu | $ 317,427 | $ 9.27 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
1,403,149 kWh 922,207 kWh |
$ 126,690 $ 82,307 |
52.56 % 34.15 % |
$ 0.087 /kWh |
- Demand Charge |
2,585 kW 1,360 kW |
$ 32,199 $ 17,244 |
37,881.18 % 20,287.06 % |
$ 0.01 /kW |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
907 MMBtu 0 MMBtu |
$ 9,990 $ 0 |
15.49 % 0.00 % |
$ 11.02 /MMBtu |
TOTAL ENERGY |
15,288 MMBtu 9,452 MMBtu |
$ 168,879 $ 99,551 |
53.20 % 31.36 % |
$ 9.27 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | 2.6231 | N | $ 2,185 | $ 9,294 | 0.24 | ||||||||||||||||
|
|||||||||||||||||||||||
| 02 | view details |
USE MULTIPLE SPEED MOTORS OR AFD FOR VARIABLE PUMP, BLOWER AND COMPRESSOR LOADS | 2.4141 | N | $ 1,355 | $ 2,063 | 0.66 | ||||||||||||||||
|
|||||||||||||||||||||||
| 03 | view details |
INSTALL OCCUPANCY SENSORS | 2.7135 | I | $ 2,016 | $ 2,458 | 0.82 | ||||||||||||||||
|
|||||||||||||||||||||||
| 04 | view details |
MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | 2.2621 | N | $ 60,000 | $ 45,262 | 1.33 | ||||||||||||||||
|
|||||||||||||||||||||||
| 05 | view details |
USE MULTIPLE SPEED MOTORS OR AFD FOR VARIABLE PUMP, BLOWER AND COMPRESSOR LOADS | 2.4141 | N | $ 2,426 | $ 1,324 | 1.83 | ||||||||||||||||
|
|||||||||||||||||||||||
| 06 | view details |
RECOVER WASTE HEAT FROM EQUIPMENT | 2.2437 | N | $ 18,610 | $ 9,259 | 2.01 | ||||||||||||||||
|
|||||||||||||||||||||||
| 07 | view details |
USE MULTIPLE SPEED MOTORS OR AFD FOR VARIABLE PUMP, BLOWER AND COMPRESSOR LOADS | 2.4141 | N | $ 1,675 | $ 853 | 1.96 | ||||||||||||||||
|
|||||||||||||||||||||||
| 08 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 118,644 | $ 89,877 | 1.32 | ||||||||||||||||
|
|||||||||||||||||||||||
| 09 | view details |
USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | 2.4322 | I | $ 24,943 | $ 4,960 | 5.03 | ||||||||||||||||
|
|||||||||||||||||||||||
| 10 | view details |
RECOVER WASTE HEAT FROM EQUIPMENT | 2.2437 | N | $ 11,479 | $ 1,273 | 9.02 | ||||||||||||||||
|
|||||||||||||||||||||||
| 11 | view details |
INSULATE BARE EQUIPMENT | 2.2511 | I | $ 22,235 | $ 2,256 | 9.86 | ||||||||||||||||
|
|||||||||||||||||||||||