Industrial Assessment Centers
Assessment #SD0507
| Assessment Year | 2011 |
|---|---|
| SIC | 2542 |
| SIC Description | Partitions And Fixtures, Except Wood |
| NAICS | 337215 |
| NAICS Description | Showcase, Partition, Shelving, and Locker Manufacturing |
| Principal Product | Office and Store Fixtures |
| Sales | $ 30,000,000 |
| # of Employees | 110 |
| Plant Area (Sq.Ft.) | 184,000 |
| Annual Production | 1,000,000 Not Available |
| Production Hrs. Annual | 2,080 |
| Location (State) | CA |
| Yearly Energy Cost | $ 239,238 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
899,565 kWh | $ 89,206 | $ 0.099 /kWh |
- Demand Charge |
5,272 kW | $ 67,159 | $ 12.74 /kW |
- Electricity Fees |
- | $ 0 | - |
Natural Gas |
12,344 MMBtu | $ 82,873 | $ 6.71 /MMBtu |
TOTAL ENERGY |
21,565 MMBtu | $ 239,238 | $ 11.09 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
96,169 kWh 3,860 kWh |
$ 9,981 $ 383 |
11.19 % 0.43 % |
$ 0.099 /kWh |
- Demand Charge |
22 kW 22 kW |
$ 284 $ 284 |
0.42 % 0.42 % |
$ 12.74 /kW |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
8,965 MMBtu 0 MMBtu |
$ 12,038 $ 0 |
14.53 % 0.00 % |
$ 6.71 /MMBtu |
TOTAL ENERGY |
9,951 MMBtu 40 MMBtu |
$ 22,303 $ 667 |
9.32 % 0.28 % |
$ 11.09 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
USE PHOTOCELL CONTROLS | 2.7134 | I | $ 0 | $ 152 | 0.00 | ||||||||||||||||
|
|||||||||||||||||||||||
| 02 | view details |
INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | 2.7447 | N | $ 5,000 | $ 11,615 | 0.43 | ||||||||||||||||
|
|||||||||||||||||||||||
| 03 | view details |
ELIMINATE OR REDUCE COMPRESSED AIR USED FOR COOLING, AGITATING LIQUIDS, MOVING PRODUCT, OR DRYING | 2.4232 | N | $ 2,500 | $ 3,820 | 0.65 | ||||||||||||||||
|
|||||||||||||||||||||||
| 04 | view details |
INSULATE FEEDWATER TANK | 2.2123 | N | $ 400 | $ 443 | 0.90 | ||||||||||||||||
|
|||||||||||||||||||||||
| 05 | view details |
USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | 2.2614 | N | $ 7,385 | $ 5,758 | 1.28 | ||||||||||||||||
|
|||||||||||||||||||||||
| 06 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 983 | $ 515 | 1.91 | ||||||||||||||||
|
|||||||||||||||||||||||