Industrial Assessment Centers
Assessment #OR0132
| Assessment Year | 1991 |
|---|---|
| SIC | 2092 |
| SIC Description | Fresh Or Frozen Prepared Fish |
| NAICS | |
| NAICS Description | |
| Principal Product | FROZEN FISH & SEAFOOD |
| Sales | $ 11,250,000 |
| # of Employees | 70 |
| Plant Area (Sq.Ft.) | 0 |
| Annual Production | 17,000,000 Pounds |
| Production Hrs. Annual | 8,736 |
| Location (State) | CA |
| Yearly Energy Cost | $ 191,826 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
1,934,642 kWh | $ 163,217 | $ 0.084 /kWh |
- Electricity Fees |
- | $ 0 | - |
LPG |
3,318 MMBtu | $ 28,609 | $ 8.62 /MMBtu |
TOTAL ENERGY |
23,148 MMBtu | $ 191,826 | $ 8.29 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
271,688 kWh 271,688 kWh |
$ 15,074 $ 15,074 |
9.24 % 9.24 % |
$ 0.084 /kWh |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
LPG |
178 MMBtu 178 MMBtu |
$ 1,538 $ 1,538 |
5.38 % 5.38 % |
$ 8.62 /MMBtu |
TOTAL ENERGY |
2,963 MMBtu 2,963 MMBtu |
$ 16,612 $ 16,612 |
8.66 % 8.66 % |
$ 8.29 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
INSTALL SET-BACK TIMERS | 2.6232 | I | $ 0 | $ 736 | 0.00 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 02 | view details |
SHUT OFF COOLING WATER WHEN NOT REQUIRED | 2.6216 | N | $ 0 | $ 317 | 0.00 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 03 | view details |
MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | 2.2621 | I | $ 500 | $ 2,074 | 0.24 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 04 | view details |
RECOVER AND REUSE COOLING WATER | 3.4115 | I | $ 1,727 | $ 2,804 | 0.62 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 05 | view details |
ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | 2.1233 | I | $ 1,000 | $ 1,538 | 0.65 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 06 | view details |
HEAT WATER WITH EXHAUST HEAT | 2.2447 | I | $ 5,744 | $ 6,513 | 0.88 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 07 | view details |
USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | 2.4133 | I | $ 5,922 | $ 878 | 6.74 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 08 | view details |
USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | 2.2694 | I | $ 1,200 | $ 1,040 | 1.15 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 09 | view details |
USE MORE EFFICIENT LIGHT SOURCE | 2.7143 | I | $ 898 | $ 632 | 1.42 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 10 | view details |
UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | 2.4111 | I | $ 10,200 | $ 3,450 | 2.96 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||