Industrial Assessment Centers
Assessment #OK0341
| Assessment Year | 1991 |
|---|---|
| SIC | 3996 |
| SIC Description | Hard Surface Floor Coverings, Nec |
| NAICS | |
| NAICS Description | |
| Principal Product | VINYL FLOOR COVERING |
| Sales | $ 80,000,000 |
| # of Employees | 200 |
| Plant Area (Sq.Ft.) | 0 |
| Annual Production | 154 Thousand Feet |
| Production Hrs. Annual | 4,000 |
| Location (State) | OK |
| Yearly Energy Cost | $ 908,164 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
13,649,180 kWh | $ 579,310 | $ 0.042 /kWh |
- Electricity Fees |
- | $ 0 | - |
Natural Gas |
151,090 MMBtu | $ 328,854 | $ 2.18 /MMBtu |
TOTAL ENERGY |
290,994 MMBtu | $ 908,164 | $ 3.12 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
1,042,204 kWh 1,042,204 kWh |
$ 38,682 $ 38,682 |
6.68 % 6.68 % |
$ 0.042 /kWh |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
14,785 MMBtu 14,785 MMBtu |
$ 31,048 $ 31,048 |
9.44 % 9.44 % |
$ 2.18 /MMBtu |
TOTAL ENERGY |
25,467 MMBtu 25,467 MMBtu |
$ 69,730 $ 69,730 |
7.68 % 7.68 % |
$ 3.12 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
INSTALL TIMERS AND/OR THERMOSTATS | 2.7261 | I | $ 245 | $ 355 | 0.69 | ||||||||||||||||
|
|||||||||||||||||||||||
| 02 | view details |
UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | 2.4111 | I | $ 6,200 | $ 4,004 | 1.55 | ||||||||||||||||
|
|||||||||||||||||||||||
| 03 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 791 | $ 1,241 | 0.64 | ||||||||||||||||
|
|||||||||||||||||||||||
| 04 | view details |
LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | 2.7141 | I | $ 38,500 | $ 14,080 | 2.73 | ||||||||||||||||
|
|||||||||||||||||||||||
| 05 | view details |
INSTALL TIMERS AND/OR THERMOSTATS | 2.7261 | I | $ 1,800 | $ 1,481 | 1.22 | ||||||||||||||||
|
|||||||||||||||||||||||
| 06 | view details |
INSTALL SET-BACK TIMERS | 2.6232 | I | $ 13,510 | $ 19,001 | 0.71 | ||||||||||||||||
|
|||||||||||||||||||||||
| 07 | view details |
USE MORE EFFICIENT LIGHT SOURCE | 2.7143 | I | $ 1,336 | $ 846 | 1.58 | ||||||||||||||||
|
|||||||||||||||||||||||
| 08 | view details |
REPAIR LEAKS IN LINES AND VALVES | 2.2133 | I | $ 740 | $ 443 | 1.67 | ||||||||||||||||
|
|||||||||||||||||||||||
| 09 | view details |
INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | 2.4221 | I | $ 2,900 | $ 2,226 | 1.30 | ||||||||||||||||
|
|||||||||||||||||||||||
| 10 | view details |
USE FLUE GAS HEAT TO PREHEAT BOILER FEEDWATER | 2.2412 | I | $ 16,500 | $ 26,053 | 0.63 | ||||||||||||||||
|
|||||||||||||||||||||||