Industrial Assessment Centers
Assessment #NC0453
| Assessment Year | 2012 |
|---|---|
| SIC | 8412 |
| SIC Description | Museums And Art Galleries |
| NAICS | 712110 |
| NAICS Description | Museums |
| Principal Product | Museum |
| Sales | $ 80,001 |
| # of Employees | 20 |
| Plant Area (Sq.Ft.) | 72,000 |
| Annual Production | 1 Not Available |
| Production Hrs. Annual | 3,000 |
| Location (State) | NC |
| Yearly Energy Cost | $ 188,597 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
1,382,016 kWh | $ 93,175 | $ 0.067 /kWh |
- Demand Charge |
3,455 kW | $ 53,251 | $ 15.41 /kW |
- Electricity Fees |
- | $ 0 | - |
Natural Gas |
4,516 MMBtu | $ 42,171 | $ 9.34 /MMBtu |
TOTAL ENERGY |
18,682 MMBtu | $ 188,597 | $ 10.10 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
138,056 kWh 0 kWh |
$ 17,983 $ 0 |
19.30 % 0.00 % |
$ 0.067 /kWh |
- Demand Charge |
438 kW 0 kW |
$ 40,777 $ 0 |
76.58 % 0.00 % |
$ 15.41 /kW |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
64 MMBtu 0 MMBtu |
$ 598 $ 0 |
1.42 % 0.00 % |
$ 9.34 /MMBtu |
TOTAL ENERGY |
1,196 MMBtu 0 MMBtu |
$ 52,350 $ 0 |
27.76 % 0.00 % |
$ 10.10 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | 2.8114 | N | $ 21,000 | $ 36,712 | 0.57 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 02 | view details |
CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | 2.7211 | N | $ 3,000 | $ 1,450 | 2.07 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 03 | view details |
ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | 2.1233 | N | $ 1,000 | $ 598 | 1.67 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 04 | view details |
USE DEIONIZED WATER IN UPSTREAM RINSE TANKS | 3.4132 | N | $ 5,000 | $ 4,110 | 1.22 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 05 | view details |
REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | 2.7224 | N | $ 0 | $ 1,077 | 0.00 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 06 | view details |
USE MORE EFFICIENT LIGHT SOURCE | 2.7143 | N | $ 600 | $ 1,330 | 0.45 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 07 | view details |
USE MORE EFFICIENT LIGHT SOURCE | 2.7143 | N | $ 1,080 | $ 650 | 1.66 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 08 | view details |
INSTALL OCCUPANCY SENSORS | 2.7135 | N | $ 352 | $ 240 | 1.47 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 09 | view details |
USE MORE EFFICIENT LIGHT SOURCE | 2.7143 | N | $ 16,470 | $ 7,228 | 2.28 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 10 | view details |
USE MORE EFFICIENT LIGHT SOURCE | 2.7143 | N | $ 16,220 | $ 4,747 | 3.42 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||