Industrial Assessment Centers
Assessment #NC0035
| Assessment Year | 1994 |
|---|---|
| SIC | 2514 |
| SIC Description | Metal Household Furniture |
| NAICS | |
| NAICS Description | |
| Principal Product | Wood / Metal Kitchen Furniture |
| Sales | $ 27,000,000 |
| # of Employees | 400 |
| Plant Area (Sq.Ft.) | 445,000 |
| Annual Production | 0 Not Available |
| Production Hrs. Annual | 2,000 |
| Location (State) | NC |
| Yearly Energy Cost | $ 359,115 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
4,615,475 kWh | $ 261,008 | $ 0.057 /kWh |
- Electricity Fees |
- | $ 0 | - |
LPG |
8,462 MMBtu | $ 67,709 | $ 8.00 /MMBtu |
Fuel Oil #2 |
6,305 MMBtu | $ 30,398 | $ 4.82 /MMBtu |
Wood |
17,325 MMBtu | $ 0 | $ 0.00 /MMBtu |
TOTAL ENERGY |
79,401 MMBtu | $ 359,115 | $ 4.52 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
286,342 kWh 160,903 kWh |
$ 16,321 $ 9,175 |
6.25 % 3.52 % |
$ 0.057 /kWh |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
LPG |
0 MMBtu 0 MMBtu |
$ 0 $ 0 |
0.00 % 0.00 % |
$ 8.00 /MMBtu |
Fuel Oil #2 |
2,644 MMBtu 0 MMBtu |
$ 15,141 $ 0 |
49.81 % 0.00 % |
$ 4.82 /MMBtu |
Wood |
0 MMBtu 0 MMBtu |
$ 0 $ 0 |
0.00 % 0.00 % |
$ 0.00 /MMBtu |
TOTAL ENERGY |
5,578 MMBtu 1,649 MMBtu |
$ 31,462 $ 9,175 |
8.76 % 2.55 % |
$ 4.52 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | 2.4236 | I | $ 1,620 | $ 5,391 | 0.30 | ||||||||||||
|
|||||||||||||||||||
| 02 | view details |
INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | 2.4221 | N | $ 700 | $ 1,132 | 0.62 | ||||||||||||
|
|||||||||||||||||||
| 03 | view details |
RECOVER HEAT FROM COMPRESSED AIR DRYERS | 2.2435 | N | $ 500 | $ 1,131 | 0.44 | ||||||||||||
|
|||||||||||||||||||
| 04 | view details |
TURN OFF EQUIPMENT WHEN NOT IN USE | 2.6218 | I | $ 0 | $ 824 | 0.00 | ||||||||||||
|
|||||||||||||||||||
| 05 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | N | $ 1,085 | $ 3,711 | 0.29 | ||||||||||||
|
|||||||||||||||||||
| 06 | view details |
REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | 2.7111 | N | $ 820 | $ 664 | 1.23 | ||||||||||||
|
|||||||||||||||||||
| 07 | view details |
IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | 2.7243 | N | $ 17,200 | $ 7,987 | 2.15 | ||||||||||||
|
|||||||||||||||||||
| 08 | view details |
INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | 2.7241 | N | $ 2,000 | $ 1,639 | 1.22 | ||||||||||||
|
|||||||||||||||||||
| 09 | view details |
USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | 2.4133 | I | $ 9,280 | $ 2,960 | 3.14 | ||||||||||||
|
|||||||||||||||||||
| 10 | view details |
RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | 2.2443 | N | $ 3,650 | $ 6,023 | 0.61 | ||||||||||||
|
|||||||||||||||||||