Industrial Assessment Centers

Assessment #MO0032


Assessment Year 1991
SIC 2339
SIC Description Women's, Misses', and Juniors' Outerwear, Not Elsewhere Classified
NAICS
NAICS Description
Principal Product WOMEN'S SPORTSWEAR
Sales $ 10,000,000
# of Employees 113
Plant Area (Sq.Ft.) 0
Annual Production 185,000 Pieces
Production Hrs. Annual 1,875
Location (State) MO
Yearly Energy Cost $ 33,201

Current Energy Usage & Costs

Energy Sources Yearly Usage Yearly Cost Unit Price

Electricity

225,381 kWh $ 16,687 $ 0.074 /kWh

- Electricity Fees

- $ 0 -

Natural Gas

3,896 MMBtu $ 16,514 $ 4.24 /MMBtu

TOTAL ENERGY

6,206 MMBtu $ 33,201 $ 5.35 /MMBtu

Recommended Reduction in Usage & Costs

Recommended
Implemented
Energy Sources Yearly Savings Yearly Cost % Saved Unit Price

Electricity

25,499 kWh
25,499 kWh
$ 1,899
$ 1,899
11.38 %
11.38 %
$ 0.074 /kWh

- Electricity Fees

- $ 0
$ 0
0.00 %
0.00 %
-

Natural Gas

230 MMBtu
230 MMBtu
$ 977
$ 977
5.92 %
5.92 %
$ 4.24 /MMBtu

TOTAL ENERGY

491 MMBtu
491 MMBtu
$ 2,876
$ 2,876
8.66 %
8.66 %
$ 5.35 /MMBtu

Recommendations

AR # Description ARC Code Status Cost Savings Payback
(Years)
01 view
details
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS 2.7142 I $ 92 $ 519 0.18
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

7,034 kWh $ 519 $ 0.074 /kWh

TOTAL ENERGY

72 MMBtu $ 519 -
02 view
details
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS 2.7142 I $ 721 $ 175 4.12
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

2,345 kWh $ 175 $ 0.074 /kWh

TOTAL ENERGY

24 MMBtu $ 175 -
03 view
details
ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO 2.1233 I $ 1,195 $ 977 1.22
Energy Sources Yearly Reduction Yearly Savings Unit Price

Natural Gas

230 MMBtu $ 977 $ 4.24 /MMBtu

TOTAL ENERGY

230 MMBtu $ 977 -
04 view
details
INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS 2.4221 I $ 368 $ 1,011 0.36
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

13,482 kWh $ 1,011 $ 0.074 /kWh

TOTAL ENERGY

138 MMBtu $ 1,011 -
05 view
details
REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED 2.4231 I $ 50 $ 168 0.30
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

2,345 kWh $ 168 $ 0.074 /kWh

TOTAL ENERGY

24 MMBtu $ 168 -
06 view
details
UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS 2.4111 I $ 0 $ 26 0.00
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

293 kWh $ 26 $ 0.074 /kWh

TOTAL ENERGY

3 MMBtu $ 26 -