Industrial Assessment Centers
Assessment #MA0699
| Assessment Year | 2012 |
|---|---|
| SIC | 3675 |
| SIC Description | Electronic Capacitors |
| NAICS | 334414 |
| NAICS Description | Electronic Capacitor Manufacturing |
| Principal Product | Tantalum capacitors |
| Sales | $ 31,000,000 |
| # of Employees | 158 |
| Plant Area (Sq.Ft.) | 64,000 |
| Annual Production | 760,000 Pieces |
| Production Hrs. Annual | 6,240 |
| Location (State) | VT |
| Yearly Energy Cost | $ 410,394 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
2,993,941 kWh | $ 214,442 | $ 0.072 /kWh |
- Demand Charge |
7,557 kW | $ 131,780 | $ 17.44 /kW |
- Electricity Fees |
- | $ 0 | - |
Fuel Oil #2 |
2,455 MMBtu | $ 64,172 | $ 26.14 /MMBtu |
TOTAL ENERGY |
33,143 MMBtu | $ 410,394 | $ 12.38 /MMBtu |
Water Disposal |
794,000 Gal | $ 1,890 | $ 0 /Gal |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
495,315 kWh 469,539 kWh |
$ 35,661 $ 33,806 |
16.63 % 15.76 % |
$ 0.072 /kWh |
- Demand Charge |
348 kW 348 kW |
$ 6,068 $ 6,068 |
4.60 % 4.60 % |
$ 17.44 /kW |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Fuel Oil #2 |
454 MMBtu 454 MMBtu |
$ 11,868 $ 11,868 |
18.49 % 18.49 % |
$ 26.14 /MMBtu |
TOTAL ENERGY |
5,531 MMBtu 5,267 MMBtu |
$ 53,597 $ 51,742 |
13.06 % 12.61 % |
$ 12.38 /MMBtu |
Water Disposal |
0 Gal 0 Gal |
$ 0 $ 0 |
0.00 % 0.00 % |
$ 0 /Gal |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
INSTALL TIMERS AND/OR THERMOSTATS | 2.7261 | I | $ 9,900 | $ 25,140 | 0.39 | ||||||||||||||||
|
|||||||||||||||||||||||
| 02 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 104,325 | $ 19,627 | 5.32 | ||||||||||||||||
|
|||||||||||||||||||||||
| 03 | view details |
SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | 2.2691 | I | $ 24,000 | $ 5,019 | 4.78 | ||||||||||||||||
|
|||||||||||||||||||||||
| 04 | view details |
ELIMINATE/REDUCE AN OPERATION | 3.1161 | N | $ 500 | $ 1,855 | 0.27 | ||||||||||||||||
|
|||||||||||||||||||||||
| 05 | view details |
USE HEAT PUMP FOR SPACE CONDITIONING | 2.7234 | I | $ 6,500 | $ 1,250 | 5.20 | ||||||||||||||||
|
|||||||||||||||||||||||
| 06 | view details |
REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | 2.4231 | I | $ 100 | $ 706 | 0.14 | ||||||||||||||||
|
|||||||||||||||||||||||