Industrial Assessment Centers
Assessment #MA0076
| Assessment Year | 1986 |
|---|---|
| SIC | 3841 |
| SIC Description | Surgical And Medical Instruments |
| NAICS | |
| NAICS Description | |
| Principal Product | MEDICAL NEEDLES |
| Sales | $ 5,000,000 |
| # of Employees | 115 |
| Plant Area (Sq.Ft.) | 0 |
| Annual Production | 100,000,000 Pieces |
| Production Hrs. Annual | 3,480 |
| Location (State) | CT |
| Yearly Energy Cost | $ 92,749 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
912,075 kWh | $ 75,894 | $ 0.083 /kWh |
- Electricity Fees |
- | $ 0 | - |
Natural Gas |
2,216 MMBtu | $ 16,855 | $ 7.61 /MMBtu |
TOTAL ENERGY |
11,565 MMBtu | $ 92,749 | $ 8.02 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
39,272 kWh 3,517 kWh |
$ 3,272 $ 306 |
4.31 % 0.40 % |
$ 0.083 /kWh |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
671 MMBtu 608 MMBtu |
$ 5,102 $ 4,626 |
30.27 % 27.45 % |
$ 7.61 /MMBtu |
TOTAL ENERGY |
1,073 MMBtu 644 MMBtu |
$ 8,374 $ 4,932 |
9.03 % 5.32 % |
$ 8.02 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
USE DIRECT AIR SUPPLY TO EXHAUST HOODS | 2.7245 | I | $ 6,000 | $ 3,524 | 1.70 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 02 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 77 | $ 526 | 0.15 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 03 | view details |
USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | 2.7226 | N | $ 2,050 | $ 712 | 2.88 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 04 | view details |
RECOVER WASTE HEAT FROM EQUIPMENT | 2.2437 | N | $ 1,100 | $ 1,822 | 0.60 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 05 | view details |
USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | 2.7492 | I | $ 3,588 | $ 882 | 4.07 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 06 | view details |
RECOVER AND REUSE COOLING WATER | 3.4115 | N | $ 660 | $ 1,226 | 0.54 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 07 | view details |
INSTALL STORM WINDOWS AND DOORS | 2.7494 | N | $ 1,114 | $ 432 | 2.58 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||