Industrial Assessment Centers
Assessment #MA0032
| Assessment Year | 1985 |
|---|---|
| SIC | 2231 |
| SIC Description | Broadwoven Fabric Mills, Wool |
| NAICS | |
| NAICS Description | |
| Principal Product | SPECIALTY FABRICS |
| Sales | $ 25,000,000 |
| # of Employees | 400 |
| Plant Area (Sq.Ft.) | 0 |
| Annual Production | 3,459,600 Pounds |
| Production Hrs. Annual | 3,366 |
| Location (State) | NH |
| Yearly Energy Cost | $ 1,222,611 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
8,258,500 kWh | $ 569,667 | $ 0.069 /kWh |
- Electricity Fees |
- | $ 0 | - |
LPG |
25,149 MMBtu | $ 140,235 | $ 5.58 /MMBtu |
Fuel Oil #6 |
91,148 MMBtu | $ 512,709 | $ 5.63 /MMBtu |
TOTAL ENERGY |
200,947 MMBtu | $ 1,222,611 | $ 6.08 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
2,975,967 kWh 223,036 kWh |
$ 205,335 $ 15,387 |
36.04 % 2.70 % |
$ 0.069 /kWh |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
LPG |
2,027 MMBtu 0 MMBtu |
$ 11,311 $ 0 |
8.07 % 0.00 % |
$ 5.58 /MMBtu |
Fuel Oil #6 |
10,949 MMBtu 0 MMBtu |
$ 61,605 $ 0 |
12.02 % 0.00 % |
$ 5.63 /MMBtu |
TOTAL ENERGY |
43,479 MMBtu 2,286 MMBtu |
$ 278,251 $ 15,387 |
22.76 % 1.26 % |
$ 6.08 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | 2.1221 | N | $ 52,000 | $ 51,867 | 1.00 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 02 | view details |
MODIFY DYE BECK | 2.5191 | N | $ 1,800 | $ 4,749 | 0.38 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 03 | view details |
BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | 2.3413 | N | $ 82,500 | $ 41,282 | 2.00 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 04 | view details |
USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | 2.3415 | N | $ 126,200 | $ 173,755 | 0.73 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 05 | view details |
RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | 2.2443 | N | $ 24,900 | $ 11,311 | 2.20 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 06 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 2,400 | $ 14,902 | 0.16 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 07 | view details |
INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | 2.4221 | I | $ 120 | $ 485 | 0.25 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||