Industrial Assessment Centers
Assessment #LL0347
| Assessment Year | 2011 |
|---|---|
| SIC | 1446 |
| SIC Description | Industrial Sand |
| NAICS | 212322 |
| NAICS Description | Industrial Sand Mining |
| Principal Product | Sand and Gravel |
| Sales | $ 7,600,000 |
| # of Employees | 17 |
| Plant Area (Sq.Ft.) | 4,800,000 |
| Annual Production | 1,100,000 Tons |
| Production Hrs. Annual | 8,112 |
| Location (State) | LA |
| Yearly Energy Cost | $ 604,599 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
8,899,800 kWh | $ 434,510 | $ 0.049 /kWh |
- Demand Charge |
24,298 kW | $ 170,089 | $ 7.00 /kW |
- Electricity Fees |
- | $ 0 | - |
TOTAL ENERGY |
91,224 MMBtu | $ 604,599 | $ 6.63 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
1,213,828 kWh 0 kWh |
$ 59,258 $ 0 |
13.64 % 0.00 % |
$ 0.049 /kWh |
- Demand Charge |
1 kW 0 kW |
$ 6 $ 0 |
0.00 % 0.00 % |
$ 7.00 /kW |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
TOTAL ENERGY |
12,442 MMBtu 0 MMBtu |
$ 59,265 $ 0 |
9.80 % 0.00 % |
$ 6.63 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
USE ADJUSTABLE FREQUENCY DRIVE TO REPLACE MECHANICAL DRIVE | 2.4144 | N | $ 166,176 | $ 53,145 | 3.13 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 02 | view details |
BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | 4.611 | N | $ 330 | $ 3,308 | 0.10 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 03 | view details |
REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | 2.4231 | N | $ 30 | $ 1,835 | 0.02 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 04 | view details |
REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | 2.7224 | N | $ 180 | $ 1,754 | 0.10 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 05 | view details |
USE PHOTOCELL CONTROLS | 2.7134 | N | $ 30 | $ 352 | 0.09 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 06 | view details |
INSTALL OCCUPANCY SENSORS | 2.7135 | N | $ 525 | $ 223 | 2.35 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 07 | view details |
USE MORE EFFICIENT LIGHT SOURCE | 2.7143 | N | $ 70 | $ 99 | 0.70 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 08 | view details |
CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | 2.6211 | N | $ 184 | $ 85 | 2.16 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 09 | view details |
REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | 2.7224 | N | $ 66 | $ 24 | 2.75 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||