Assessment #LL0289
| Assessment Year | 2008 |
|---|---|
| SIC | 3011 |
| SIC Description | Tires And Inner Tubes |
| NAICS | 326211 |
| NAICS Description | Tire Manufacturing (except Retreading) |
| Principal Product | Tires |
| Sales | $ 50,000,000 |
| # of Employees | 1,550 |
| Plant Area (Sq.Ft.) | 1,918,000 |
| Annual Production | 9,500,000 Pieces |
| Production Hrs. Annual | 7,344 |
| Location (State) | AR |
| Yearly Energy Cost | $ 10,828,973 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
148,684,000 kWh | $ 5,201,937 | $ 0.035 /kWh |
- Demand Charge |
254,735 kW | $ 1,277,437 | $ 5.01 /kW |
- Electricity Fees |
- | $ 258,457 | - |
Natural Gas |
590,191 MMBtu | $ 4,091,142 | $ 6.93 /MMBtu |
TOTAL ENERGY |
2,114,202 MMBtu | $ 10,828,973 | $ 5.12 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
7,631,685 kWh 7,550,692 kWh |
$ 267,033 $ 264,199 |
5.13 % 5.08 % |
$ 0.035 /kWh |
- Demand Charge |
174 kW 0 kW |
$ 871 $ 0 |
0.07 % 0.00 % |
$ 5.01 /kW |
- Electricity Fees |
- |
$ 10,716 $ 10,568 |
4.15 % 4.09 % |
- |
Natural Gas |
23,956 MMBtu 15,966 MMBtu |
$ 166,046 $ 110,633 |
4.06 % 2.70 % |
$ 6.93 /MMBtu |
TOTAL ENERGY |
102,182 MMBtu 93,361 MMBtu |
$ 444,666 $ 385,400 |
4.11 % 3.56 % |
$ 5.12 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | 2.4236 | I | $ 187,520 | $ 274,767 | 0.68 | ||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||
| 02 | view details |
REPAIR AND ELIMINATE STEAM LEAKS | 2.2135 | I | $ 3,650 | $ 110,300 | 0.03 | ||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||
| 03 | view details |
DIRECT WARMEST AIR TO COMBUSTION INTAKE | 2.1213 | N | $ 1,290 | $ 47,583 | 0.03 | ||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||
| 04 | view details |
BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | 4.611 | N | $ 11,905 | $ 21,390 | 0.56 | ||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||
| 05 | view details |
INSULATE BARE EQUIPMENT | 2.2511 | N | $ 1,940 | $ 7,830 | 0.25 | ||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||
| 06 | view details |
USE MORE EFFICIENT LIGHT SOURCE | 2.7143 | N | $ 3,500 | $ 4,497 | 0.78 | ||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||
| 07 | view details |
REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | 2.7111 | N | $ 1,710 | $ 1,820 | 0.94 | ||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||
| 08 | view details |
CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | 2.6211 | N | $ 1,402 | $ 572 | 2.45 | ||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||
| 09 | view details |
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | 2.4236 | I | $ 165 | $ 333 | 0.50 | ||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||