Industrial Assessment Centers
Assessment #KU0298
| Assessment Year | 1989 |
|---|---|
| SIC | 3089 |
| SIC Description | Plastics Products, Nec |
| NAICS | |
| NAICS Description | |
| Principal Product | INJECTION MOLDED PARTS |
| Sales | $ 7,000,000 |
| # of Employees | 195 |
| Plant Area (Sq.Ft.) | 0 |
| Annual Production | 2,000,000 Pounds |
| Production Hrs. Annual | 6,000 |
| Location (State) | NE |
| Yearly Energy Cost | $ 194,062 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
3,629,836 kWh | $ 187,649 | $ 0.052 /kWh |
- Electricity Fees |
- | $ 0 | - |
Natural Gas |
1,545 MMBtu | $ 6,413 | $ 4.15 /MMBtu |
TOTAL ENERGY |
38,751 MMBtu | $ 194,062 | $ 5.01 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
177,315 kWh 117,819 kWh |
$ 8,786 $ 5,858 |
4.68 % 3.12 % |
$ 0.052 /kWh |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
346 MMBtu 0 MMBtu |
$ 1,436 $ 0 |
22.39 % 0.00 % |
$ 4.15 /MMBtu |
TOTAL ENERGY |
2,163 MMBtu 1,207 MMBtu |
$ 10,222 $ 5,858 |
5.27 % 3.02 % |
$ 5.01 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 382 | $ 1,437 | 0.27 | ||||||||||||||||
|
|||||||||||||||||||||||
| 02 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 76 | $ 380 | 0.20 | ||||||||||||||||
|
|||||||||||||||||||||||
| 03 | view details |
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | 2.4236 | I | $ 100 | $ 2,572 | 0.04 | ||||||||||||||||
|
|||||||||||||||||||||||
| 04 | view details |
USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | 2.4133 | I | $ 300 | $ 261 | 1.15 | ||||||||||||||||
|
|||||||||||||||||||||||
| 05 | view details |
USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | 2.2614 | N | $ 3,700 | $ 1,951 | 1.90 | ||||||||||||||||
|
|||||||||||||||||||||||
| 06 | view details |
ISOLATE HOT OR COLD EQUIPMENT | 2.2522 | N | $ 1,800 | $ 1,026 | 1.75 | ||||||||||||||||
|
|||||||||||||||||||||||
| 07 | view details |
RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | 2.2443 | N | $ 700 | $ 856 | 0.82 | ||||||||||||||||
|
|||||||||||||||||||||||
| 08 | view details |
INSULATE BARE EQUIPMENT | 2.2511 | I | $ 310 | $ 727 | 0.43 | ||||||||||||||||
|
|||||||||||||||||||||||
| 09 | view details |
INSTALL AUTOMATIC STACK DAMPER | 2.1123 | N | $ 1,020 | $ 531 | 1.92 | ||||||||||||||||
|
|||||||||||||||||||||||
| 10 | view details |
REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | 2.6121 | I | $ 0 | $ 361 | 0.00 | ||||||||||||||||
|
|||||||||||||||||||||||
| 11 | view details |
REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | 2.6121 | I | $ 0 | $ 120 | 0.00 | ||||||||||||||||
|
|||||||||||||||||||||||
