Industrial Assessment Centers
Assessment #KU0148
| Assessment Year | 1984 |
|---|---|
| SIC | 3699 |
| SIC Description | Electrical Equipment & Supplies, Nec |
| NAICS | |
| NAICS Description | |
| Principal Product | AVIATION ELECTRONICS |
| Sales | $ 35,000,000 |
| # of Employees | 350 |
| Plant Area (Sq.Ft.) | 0 |
| Annual Production | 25,000 Pieces |
| Production Hrs. Annual | 6,000 |
| Location (State) | KS |
| Yearly Energy Cost | $ 103,595 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
1,315,944 kWh | $ 94,060 | $ 0.071 /kWh |
- Electricity Fees |
- | $ 0 | - |
Natural Gas |
2,034 MMBtu | $ 9,535 | $ 4.69 /MMBtu |
TOTAL ENERGY |
15,522 MMBtu | $ 103,595 | $ 6.67 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
294,256 kWh 88,805 kWh |
$ 23,783 $ 9,094 |
25.28 % 9.67 % |
$ 0.071 /kWh |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
1,890 MMBtu 1,986 MMBtu |
$ 8,862 $ 9,315 |
92.94 % 97.69 % |
$ 4.69 /MMBtu |
TOTAL ENERGY |
4,905 MMBtu 2,896 MMBtu |
$ 32,645 $ 18,409 |
31.51 % 17.77 % |
$ 6.67 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 36 | $ 4,910 | 0.01 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 02 | view details |
USE DEMAND CONTROLLER OR LOAD SHEDDER | 2.3191 | I | $ 3,000 | $ 2,754 | 1.09 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 03 | view details |
ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | 2.1233 | I | $ 800 | $ 514 | 1.56 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 04 | view details |
INSTALL AUTOMATIC STACK DAMPER | 2.1123 | I | $ 700 | $ 436 | 1.61 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 05 | view details |
REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | 2.1131 | I | $ 100 | $ 366 | 0.27 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 06 | view details |
INSULATE BARE EQUIPMENT | 2.2511 | N | $ 70 | $ 173 | 0.40 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 07 | view details |
INSULATE BARE EQUIPMENT | 2.2511 | N | $ 1,240 | $ 1,738 | 0.71 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 08 | view details |
RECOVER WASTE HEAT FROM EQUIPMENT | 2.2437 | N | $ 150 | $ 99 | 1.52 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 09 | view details |
REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | 2.7441 | I | $ 12 | $ 298 | 0.04 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 10 | view details |
REDUCE VENTILATION AIR | 2.7314 | I | $ 500 | $ 2,954 | 0.17 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 11 | view details |
USE MULTIPLE SPEED MOTORS OR AFD FOR VARIABLE PUMP, BLOWER AND COMPRESSOR LOADS | 2.4141 | N | $ 15,000 | $ 10,658 | 1.41 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 12 | view details |
LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | 2.7221 | I | $ 17 | $ 4,177 | 0.00 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 13 | view details |
IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | 2.7243 | I | $ 2,000 | $ 1,182 | 1.69 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 14 | view details |
REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | 2.6121 | I | $ 0 | $ 760 | 0.00 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 15 | view details |
REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | 2.1311 | N | $ 1,900 | $ 1,508 | 1.26 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||