Industrial Assessment Centers

Assessment #HO0207


Assessment Year 1999
SIC 3812
SIC Description Search And Navigation Equipment
NAICS
NAICS Description
Principal Product Gyroscopes
Sales $ 50,000,000
# of Employees 420
Plant Area (Sq.Ft.) 132,000
Annual Production 39,000 Pounds
Production Hrs. Annual 5,760
Location (State) CT
Yearly Energy Cost $ 1,262,317

Current Energy Usage & Costs

Energy Sources Yearly Usage Yearly Cost Unit Price

Electricity

15,550,997 kWh $ 880,647 $ 0.057 /kWh

- Demand Charge

28,192 kW $ 289,416 $ 10.27 /kW

- Electricity Fees

- $ -209,346 -

Natural Gas

57,834 MMBtu $ 301,600 $ 5.21 /MMBtu

TOTAL ENERGY

217,232 MMBtu $ 1,262,317 $ 5.81 /MMBtu

Recommended Reduction in Usage & Costs

Recommended
Implemented
Energy Sources Yearly Savings Yearly Cost % Saved Unit Price

Electricity

757,913 kWh
727,139 kWh
$ 42,876
$ 41,138
4.87 %
4.67 %
$ 0.057 /kWh

- Demand Charge

772 kW
772 kW
$ 7,920
$ 7,920
2.74 %
2.74 %
$ 10.27 /kW

- Electricity Fees

- $ 0
$ 0
0.00 %
0.00 %
-

Natural Gas

364 MMBtu
0 MMBtu
$ 1,898
$ 0
0.63 %
0.00 %
$ 5.21 /MMBtu

TOTAL ENERGY

8,132 MMBtu
7,453 MMBtu
$ 52,694
$ 49,058
4.17 %
3.89 %
$ 5.81 /MMBtu

Recommendations

AR # Description ARC Code Status Cost Savings Payback
(Years)
01 view
details
REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS 2.7111 I $ 600 $ 28,880 0.02
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

370,457 kWh $ 20,960 $ 0.057 /kWh

- Demand Charge

772 kW $ 7,920 $ 10.27 /kW

TOTAL ENERGY

3,797 MMBtu $ 28,880 -
02 view
details
TURN OFF EQUIPMENT WHEN NOT IN USE 2.6218 I $ 15,000 $ 11,756 1.28
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

207,796 kWh $ 11,756 $ 0.057 /kWh

TOTAL ENERGY

2,130 MMBtu $ 11,756 -
03 view
details
INSTALL OCCUPANCY SENSORS 2.7135 I $ 10,000 $ 5,242 1.91
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

92,614 kWh $ 5,242 $ 0.057 /kWh

TOTAL ENERGY

949 MMBtu $ 5,242 -
04 view
details
SHUT OFF ALL LABORATORY FUME HOODS WHEN NOT IN USE 2.6217 I $ 0 $ 2,590 0.00
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

45,721 kWh $ 2,590 $ 0.057 /kWh

TOTAL ENERGY

469 MMBtu $ 2,590 -
05 view
details
MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED 2.7124 I $ 0 $ 590 0.00
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

10,551 kWh $ 590 $ 0.057 /kWh

TOTAL ENERGY

108 MMBtu $ 590 -
06 view
details
TURN OFF EQUIPMENT WHEN NOT IN USE 2.6218 N $ 0 $ 1,738 0.00
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

30,774 kWh $ 1,738 $ 0.057 /kWh

TOTAL ENERGY

315 MMBtu $ 1,738 -
07 view
details
INSULATE STEAM / HOT WATER LINES 2.2131 N $ 2,625 $ 1,898 1.38
Energy Sources Yearly Reduction Yearly Savings Unit Price

Natural Gas

364 MMBtu $ 1,898 $ 5.21 /MMBtu

TOTAL ENERGY

364 MMBtu $ 1,898 -