Industrial Assessment Centers

Assessment #GT0862


Assessment Year 2009
SIC 3713
SIC Description Truck And Bus Bodies
NAICS 336211
NAICS Description Motor Vehicle Body Manufacturing
Principal Product Highway Coaches
Sales $ 35,000,000
# of Employees 200
Plant Area (Sq.Ft.) 212,000
Annual Production 60 Pieces
Production Hrs. Annual 3,250
Location (State) GA
Yearly Energy Cost $ 223,978

Current Energy Usage & Costs

Energy Sources Yearly Usage Yearly Cost Unit Price

Electricity

2,131,280 kWh $ 79,923 $ 0.038 /kWh

- Demand Charge

8,259 kW $ 129,130 $ 15.64 /kW

- Electricity Fees

- $ 0 -

Natural Gas

1,054 MMBtu $ 14,925 $ 14.16 /MMBtu

TOTAL ENERGY

22,900 MMBtu $ 223,978 $ 9.78 /MMBtu

Recommended Reduction in Usage & Costs

Recommended
Implemented
Energy Sources Yearly Savings Yearly Cost % Saved Unit Price

Electricity

93,334 kWh
0 kWh
$ 10,086
$ 0
12.62 %
0.00 %
$ 0.038 /kWh

- Demand Charge

113,430 kW
0 kW
$ 8,430
$ 0
6.53 %
0.00 %
$ 15.64 /kW

- Electricity Fees

- $ 0
$ 0
0.00 %
0.00 %
-

Natural Gas

0 MMBtu
0 MMBtu
$ 0
$ 0
0.00 %
0.00 %
$ 14.16 /MMBtu

TOTAL ENERGY

956 MMBtu
0 MMBtu
$ 18,516
$ 0
8.27 %
0.00 %
$ 9.78 /MMBtu

Recommendations

AR # Description ARC Code Status Cost Savings Payback
(Years)
01 view
details
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS 2.7142 N $ 17,464 $ 10,845 1.61
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

418 kWh $ 6,601 $ 0.038 /kWh

- Demand Charge

113,165 kW $ 4,244 $ 15.64 /kW

TOTAL ENERGY

4 MMBtu $ 10,845 -
02 view
details
ELIMINATE PERMANENTLY THE USE OF COMPRESSED AIR 2.4233 N $ 0 $ 962 0.00
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

25,660 kWh $ 962 $ 0.038 /kWh

TOTAL ENERGY

263 MMBtu $ 962 -
03 view
details
REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED 2.4231 N $ 0 $ 439 0.00
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

11,700 kWh $ 439 $ 0.038 /kWh

TOTAL ENERGY

120 MMBtu $ 439 -
04 view
details
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES 2.4236 N $ 500 $ 810 0.62
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

8,450 kWh $ 317 $ 0.038 /kWh

- Demand Charge

31 kW $ 493 $ 15.64 /kW

TOTAL ENERGY

87 MMBtu $ 810 -
05 view
details
UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS 2.4111 N $ 449 $ 325 1.38
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

1,119 kWh $ 42 $ 0.038 /kWh

- Demand Charge

18 kW $ 283 $ 15.64 /kW

TOTAL ENERGY

11 MMBtu $ 325 -
06 view
details
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS 2.7142 N $ 9,840 $ 3,517 2.80
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

36,725 kWh $ 1,377 $ 0.038 /kWh

- Demand Charge

136 kW $ 2,140 $ 15.64 /kW

TOTAL ENERGY

376 MMBtu $ 3,517 -
07 view
details
USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS 2.4133 N $ 11,925 $ 1,618 7.37
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

9,262 kWh $ 348 $ 0.038 /kWh

- Demand Charge

80 kW $ 1,270 $ 15.64 /kW

TOTAL ENERGY

95 MMBtu $ 1,618 -