Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
6,046,950 kWh | $ 752,528 | $ 0.124 /kWh |
- Electricity Fees |
- | $ 0 | - |
Natural Gas |
9,681 MMBtu | $ 122,814 | $ 12.69 /MMBtu |
TOTAL ENERGY |
71,663 MMBtu | $ 875,342 | $ 12.21 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
844,120 kWh 551,170 kWh |
$ 104,685 $ 68,360 |
13.91 % 9.08 % |
$ 0.124 /kWh |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
4,468 MMBtu 1,982 MMBtu |
$ 56,703 $ 25,155 |
46.17 % 20.48 % |
$ 12.69 /MMBtu |
TOTAL ENERGY |
13,121 MMBtu 7,632 MMBtu |
$ 161,388 $ 93,515 |
18.44 % 10.68 % |
$ 12.21 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | 2.7262 | N | $ 100 | $ 37,175 | 0.00 | ||||||||||||||||
|
|||||||||||||||||||||||
| 02 | view details |
REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | 2.7224 | I | $ 100 | $ 7,948 | 0.01 | ||||||||||||||||
|
|||||||||||||||||||||||
| 03 | view details |
RECOVER HEAT FROM TRANSFORMERS | 2.2431 | I | $ 6,080 | $ 9,212 | 0.66 | ||||||||||||||||
|
|||||||||||||||||||||||
| 04 | view details |
INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | 2.7241 | I | $ 21,080 | $ 25,500 | 0.83 | ||||||||||||||||
|
|||||||||||||||||||||||
| 05 | view details |
USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | 2.4322 | I | $ 51,500 | $ 32,910 | 1.56 | ||||||||||||||||
|
|||||||||||||||||||||||
| 06 | view details |
RECOVER HEAT FROM AIR COMPRESSOR | 2.2434 | I | $ 4,850 | $ 7,995 | 0.61 | ||||||||||||||||
|
|||||||||||||||||||||||
| 07 | view details |
USE ADJUSTABLE FREQUENCY DRIVE TO REPLACE MECHANICAL DRIVE | 2.4144 | I | $ 2,800 | $ 4,020 | 0.70 | ||||||||||||||||
|
|||||||||||||||||||||||
| 08 | view details |
INSTALL OCCUPANCY SENSORS | 2.7135 | I | $ 620 | $ 2,640 | 0.23 | ||||||||||||||||
|
|||||||||||||||||||||||
| 09 | view details |
USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT COMBUSTION AIR | 2.2411 | N | $ 80,000 | $ 23,794 | 3.36 | ||||||||||||||||
|
|||||||||||||||||||||||
| 10 | view details |
REVISE SMOKE CLEANUP FROM OPERATIONS | 2.7244 | I | $ 11,200 | $ 3,290 | 3.40 | ||||||||||||||||
|
|||||||||||||||||||||||
| 11 | view details |
IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | 2.7243 | N | $ 11,040 | $ 5,894 | 1.87 | ||||||||||||||||
|
|||||||||||||||||||||||
| 12 | view details |
SHUT OFF COOLING WATER WHEN NOT REQUIRED | 2.6216 | N | $ 500 | $ 1,010 | 0.50 | ||||||||||||||||
|
|||||||||||||||||||||||