Industrial Assessment Centers
Assessment #DL0067
| Assessment Year | 2011 |
|---|---|
| SIC | 3826 |
| SIC Description | Analytical Instruments |
| NAICS | 334516 |
| NAICS Description | Analytical Laboratory Instrument Manufacturing |
| Principal Product | Thermal Analyzers |
| Sales | $ 150,000,000 |
| # of Employees | 109 |
| Plant Area (Sq.Ft.) | 170,640 |
| Annual Production | 1,800 Pieces |
| Production Hrs. Annual | 2,080 |
| Location (State) | DE |
| Yearly Energy Cost | $ 389,657 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
3,318,700 kWh | $ 336,700 | $ 0.101 /kWh |
- Demand Charge |
568 kW | $ 9,857 | $ 17.35 /kW |
- Electricity Fees |
- | $ 17,100 | - |
Natural Gas |
1,776 MMBtu | $ 26,000 | $ 14.64 /MMBtu |
TOTAL ENERGY |
35,793 MMBtu | $ 389,657 | $ 10.89 /MMBtu |
Water Disposal |
3,215,200 Gal | $ 17,800 | $ 0 /Gal |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
507,307 kWh 0 kWh |
$ 35,349 $ 0 |
10.50 % 0.00 % |
$ 0.101 /kWh |
- Demand Charge |
397 kW 0 kW |
$ 6,950 $ 0 |
70.51 % 0.00 % |
$ 17.35 /kW |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
1,431 MMBtu 0 MMBtu |
$ 22,082 $ 0 |
84.93 % 0.00 % |
$ 14.64 /MMBtu |
TOTAL ENERGY |
6,631 MMBtu 0 MMBtu |
$ 64,381 $ 0 |
16.52 % 0.00 % |
$ 10.89 /MMBtu |
Water Disposal |
0 Gal 0 Gal |
$ 0 $ 0 |
0.00 % 0.00 % |
$ 0 /Gal |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
INSTALL SPECTRAL REFLECTORS / DELAMP | 2.7144 | N | $ 3,500 | $ 5,600 | 0.63 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 02 | view details |
TURN OFF EQUIPMENT WHEN NOT IN USE | 2.6218 | N | $ 2,600 | $ 4,300 | 0.60 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 03 | view details |
CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | 2.6211 | N | $ 780 | $ 331 | 2.36 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 04 | view details |
RECOVER WASTE HEAT FROM EQUIPMENT | 2.2437 | N | $ 1,000 | $ 5,082 | 0.20 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 05 | view details |
INSTALL OCCUPANCY SENSORS | 2.7135 | N | $ 1,500 | $ 9,000 | 0.17 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 06 | view details |
INSTALL OCCUPANCY SENSORS | 2.7135 | N | $ 3,100 | $ 4,518 | 0.69 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 07 | view details |
TURN OFF EQUIPMENT WHEN NOT IN USE | 2.6218 | N | $ 1,200 | $ 16,400 | 0.07 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||
| 08 | view details |
USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | 2.2492 | N | $ 13,200 | $ 19,150 | 0.69 | ||||||||||||||||||||
|
|||||||||||||||||||||||||||