Industrial Assessment Centers
Assessment #DL0043
| Assessment Year | 2009 |
|---|---|
| SIC | 3432 |
| SIC Description | Plumbing Fixture Fittings And Trim |
| NAICS | 332913 |
| NAICS Description | Plumbing Fixture Fitting and Trim Manufacturing |
| Principal Product | plumbing fixtures |
| Sales | $ 22,000,000 |
| # of Employees | 114 |
| Plant Area (Sq.Ft.) | 65,000 |
| Annual Production | 96,000 Pieces |
| Production Hrs. Annual | 3,120 |
| Location (State) | DE |
| Yearly Energy Cost | $ 105,865 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
663,920 kWh | $ 105,827 | $ 0.159 /kWh |
- Electricity Fees |
- | $ 0 | - |
Natural Gas |
2,556 MMBtu | $ 38 | $ 0.01 /MMBtu |
TOTAL ENERGY |
9,361 MMBtu | $ 105,865 | $ 11.31 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
9,590 kWh 0 kWh |
$ 1,430 $ 0 |
1.35 % 0.00 % |
$ 0.159 /kWh |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
1,247 MMBtu 570 MMBtu |
$ 18,954 $ 8,664 |
49,878.95 % 22,800.00 % |
$ 0.01 /MMBtu |
TOTAL ENERGY |
1,345 MMBtu 570 MMBtu |
$ 21,444 $ 9,724 |
20.26 % 9.19 % |
$ 11.31 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | 2.7243 | N | $ 18,300 | $ 9,690 | 1.89 | ||||||||||||
|
|||||||||||||||||||
| 02 | view details |
LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | 2.7221 | I | $ 0 | $ 3,192 | 0.00 | ||||||||||||
|
|||||||||||||||||||
| 03 | view details |
REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | 2.7232 | I | $ 3,500 | $ 5,472 | 0.64 | ||||||||||||
|
|||||||||||||||||||
| 04 | view details |
RECOVER HEAT FROM AIR COMPRESSOR | 2.2434 | N | $ 950 | $ 600 | 1.58 | ||||||||||||
|
|||||||||||||||||||
| 05 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | N | $ 2,000 | $ 960 | 2.08 | ||||||||||||
|
|||||||||||||||||||
| 06 | view details |
CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | 2.6211 | N | $ 510 | $ 470 | 1.09 | ||||||||||||
|
|||||||||||||||||||
| 07 | view details |
RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | 2.3131 | I | $ 0 | $ 1,060 | 0.00 | ||||||||||||
|
|||||||||||||||||||