Industrial Assessment Centers

Assessment #CO0519


Assessment Year 2002
SIC 2099
SIC Description Food Preparations, Nec
NAICS 311411
NAICS Description Frozen Fruit, Juice, and Vegetable Manufacturing
Principal Product frozen green chile peppers, tortillas
Sales $ 50,000,000
# of Employees 200
Plant Area (Sq.Ft.) 120,500
Annual Production 8,000,000 Pounds
Production Hrs. Annual 6,552
Location (State) NM
Yearly Energy Cost $ 505,296

Current Energy Usage & Costs

Energy Sources Yearly Usage Yearly Cost Unit Price

Electricity

6,307,200 kWh $ 253,401 $ 0.040 /kWh

- Demand Charge

11,979 kW $ 69,241 $ 5.78 /kW

- Electricity Fees

- $ 70,732 -

Natural Gas

26,748 MMBtu $ 111,922 $ 4.18 /MMBtu

TOTAL ENERGY

91,397 MMBtu $ 505,296 $ 5.53 /MMBtu

Recommended Reduction in Usage & Costs

Recommended
Implemented
Energy Sources Yearly Savings Yearly Cost % Saved Unit Price

Electricity

117,351 kWh
72,251 kWh
$ 4,758
$ 2,908
1.88 %
1.15 %
$ 0.040 /kWh

- Demand Charge

188 kW
112 kW
$ 2,165
$ 1,285
3.13 %
1.86 %
$ 5.78 /kW

- Electricity Fees

- $ 0
$ 0
0.00 %
0.00 %
-

Natural Gas

1,171 MMBtu
0 MMBtu
$ 4,990
$ 0
4.46 %
0.00 %
$ 4.18 /MMBtu

TOTAL ENERGY

2,374 MMBtu
741 MMBtu
$ 11,913
$ 4,193
2.36 %
0.83 %
$ 5.53 /MMBtu

Recommendations

AR # Description ARC Code Status Cost Savings Payback
(Years)
01 view
details
INSULATE BARE EQUIPMENT 2.2511 N $ 1,350 $ 5,560 0.24
Energy Sources Yearly Reduction Yearly Savings Unit Price

Natural Gas

1,304 MMBtu $ 5,560 $ 4.18 /MMBtu

TOTAL ENERGY

1,304 MMBtu $ 5,560 -
02 view
details
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS 2.7142 I $ 5,292 $ 2,972 1.78
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

46,850 kWh $ 1,860 $ 0.040 /kWh

- Demand Charge

67 kW $ 776 $ 5.78 /kW

TOTAL ENERGY

480 MMBtu $ 2,636 -

Ancillary Material Cost

- $ 336 -

TOTAL PRODUCTON

- $ 336 -
03 view
details
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS 2.7142 I $ 3,156 $ 954 3.31
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

16,596 kWh $ 682 $ 0.040 /kWh

- Demand Charge

28 kW $ 318 $ 5.78 /kW

TOTAL ENERGY

170 MMBtu $ 1,000 -

Ancillary Material Cost

- $ -46 -

TOTAL PRODUCTON

- $ -46 -
04 view
details
UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS 2.4111 N $ 2,700 $ 1,390 1.94
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

31,200 kWh $ 1,300 $ 0.040 /kWh

- Demand Charge

57 kW $ 660 $ 5.78 /kW

Natural Gas

-133 MMBtu $ -570 $ 4.18 /MMBtu

TOTAL ENERGY

187 MMBtu $ 1,390 -
05 view
details
INSTALL COMMON HEADER ON COMPRESSORS 2.4225 N $ 2,740 $ 770 3.56
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

13,900 kWh $ 550 $ 0.040 /kWh

- Demand Charge

19 kW $ 220 $ 5.78 /kW

TOTAL ENERGY

142 MMBtu $ 770 -
06 view
details
USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS 2.4133 I $ 280 $ 103 2.72
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

1,817 kWh $ 72 $ 0.040 /kWh

- Demand Charge

3 kW $ 31 $ 5.78 /kW

TOTAL ENERGY

19 MMBtu $ 103 -
07 view
details
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS 2.7142 I $ 742 $ 286 2.59
Energy Sources Yearly Reduction Yearly Savings Unit Price

Electricity

6,988 kWh $ 294 $ 0.040 /kWh

- Demand Charge

14 kW $ 160 $ 5.78 /kW

TOTAL ENERGY

72 MMBtu $ 454 -

Ancillary Material Cost

- $ -168 -

TOTAL PRODUCTON

- $ -168 -