Industrial Assessment Centers
Assessment #CO0472
| Assessment Year | 2000 |
|---|---|
| SIC | 2511 |
| SIC Description | Wood Household Furniture |
| NAICS | |
| NAICS Description | |
| Principal Product | finished household furniture |
| Sales | $ 7,000,000 |
| # of Employees | 75 |
| Plant Area (Sq.Ft.) | 31,000 |
| Annual Production | 10,000 Pieces |
| Production Hrs. Annual | 4,290 |
| Location (State) | CO |
| Yearly Energy Cost | $ 64,350 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
995,604 kWh | $ 14,850 | $ 0.015 /kWh |
- Demand Charge |
3,274 kW | $ 34,811 | $ 10.63 /kW |
- Electricity Fees |
- | $ 0 | - |
Natural Gas |
3,324 MMBtu | $ 14,689 | $ 4.42 /MMBtu |
TOTAL ENERGY |
13,529 MMBtu | $ 64,350 | $ 4.76 /MMBtu |
Water Disposal |
280,000 Gal | $ 842 | $ 0 /Gal |
Solid Waste (non-haz) |
2,340,000 lbs | $ 9,360 | $ 0 /lbs |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
35,757 kWh 30,188 kWh |
$ 530 $ 450 |
3.57 % 3.03 % |
$ 0.015 /kWh |
- Demand Charge |
427 kW 84 kW |
$ 4,540 $ 890 |
13.04 % 2.56 % |
$ 10.63 /kW |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
1,186 MMBtu 1,186 MMBtu |
$ 5,320 $ 5,320 |
36.22 % 36.22 % |
$ 4.42 /MMBtu |
TOTAL ENERGY |
1,552 MMBtu 1,495 MMBtu |
$ 10,390 $ 6,660 |
16.15 % 10.35 % |
$ 4.76 /MMBtu |
Water Disposal |
0 Gal 0 Gal |
$ 0 $ 0 |
0.00 % 0.00 % |
$ 0 /Gal |
Solid Waste (non-haz) |
0 lbs 0 lbs |
$ 0 $ 0 |
0.00 % 0.00 % |
$ 0 /lbs |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | 2.7491 | I | $ 12,550 | $ 4,280 | 2.93 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 02 | view details |
USE DEMAND CONTROLLER OR LOAD SHEDDER | 2.3191 | N | $ 200 | $ 2,960 | 0.07 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 03 | view details |
KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | 2.7442 | I | $ 1,000 | $ 1,040 | 0.96 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 04 | view details |
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | 2.4236 | I | $ 370 | $ 570 | 0.65 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 05 | view details |
UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | 2.4111 | I | $ 1,020 | $ 410 | 2.49 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 06 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | N | $ 0 | $ 130 | 0.00 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 07 | view details |
TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | 4.4310 | I | $ 1,600 | $ 35,000 | 0.05 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||