Industrial Assessment Centers
Assessment #AR0029
| Assessment Year | 1994 |
|---|---|
| SIC | 2421 |
| SIC Description | Sawmills And Planing Mills, General |
| NAICS | |
| NAICS Description | |
| Principal Product | Commerical Lumber |
| Sales | $ 33,000,000 |
| # of Employees | 236 |
| Plant Area (Sq.Ft.) | 200,000 |
| Annual Production | 100,000,000 Thousand Feet |
| Production Hrs. Annual | 4,171 |
| Location (State) | AR |
| Yearly Energy Cost | $ 1,300,480 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
9,394,197 kWh | $ 712,082 | $ 0.076 /kWh |
- Electricity Fees |
- | $ 0 | - |
Natural Gas |
263,036 MMBtu | $ 588,398 | $ 2.24 /MMBtu |
TOTAL ENERGY |
359,327 MMBtu | $ 1,300,480 | $ 3.62 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
1,852,872 kWh 239,156 kWh |
$ 140,489 $ 18,137 |
19.73 % 2.55 % |
$ 0.076 /kWh |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
-6,977 MMBtu 1,383 MMBtu |
$ -15,628 $ 3,099 |
-2.66 % 0.53 % |
$ 2.24 /MMBtu |
TOTAL ENERGY |
12,014 MMBtu 3,833 MMBtu |
$ 124,861 $ 21,236 |
9.60 % 1.63 % |
$ 3.62 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | 2.4133 | I | $ 8,050 | $ 6,142 | 1.31 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 02 | view details |
UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | 2.4111 | I | $ 1,991 | $ 7,927 | 0.25 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 03 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 327 | $ 1,836 | 0.18 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 04 | view details |
REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | 2.7111 | I | $ 1,100 | $ 2,232 | 0.49 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 05 | view details |
REPLACE ELECTRIC MOTOR WITH FOSSIL FUEL ENGINE | 2.4134 | N | $ 54,000 | $ 87,625 | 0.62 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 06 | view details |
INSULATE STEAM / HOT WATER LINES | 2.2131 | I | $ 459 | $ 3,099 | 0.15 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||