Industrial Assessment Centers
Assessment #AM0566
| Assessment Year | 2009 |
|---|---|
| SIC | 3494 |
| SIC Description | Valves And Pipe Fittings, Nec |
| NAICS | 332911 |
| NAICS Description | Industrial Valve Manufacturing |
| Principal Product | Plug, butterfly, and ball valves, connectors, pumps |
| Sales | $ 310,000,000 |
| # of Employees | 300 |
| Plant Area (Sq.Ft.) | 300,000 |
| Annual Production | 1,000,000 Pieces |
| Production Hrs. Annual | 3,860 |
| Location (State) | TX |
| Yearly Energy Cost | $ 2,128,847 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
18,986,766 kWh | $ 1,755,080 | $ 0.092 /kWh |
- Demand Charge |
65,052 kW | $ 328,183 | $ 5.04 /kW |
- Electricity Fees |
- | $ 45,584 | - |
TOTAL ENERGY |
194,614 MMBtu | $ 2,128,847 | $ 10.94 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
1,215,640 kWh 1,149,440 kWh |
$ 112,280 $ 106,180 |
6.40 % 6.05 % |
$ 0.092 /kWh |
- Demand Charge |
21,312 kW 3,312 kW |
$ 111,070 $ 17,270 |
33.84 % 5.26 % |
$ 5.04 /kW |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
TOTAL ENERGY |
12,461 MMBtu 11,782 MMBtu |
$ 223,350 $ 123,450 |
10.49 % 5.80 % |
$ 10.94 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | 2.3134 | N | $ 0 | $ 59,200 | 0.00 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 02 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 111,190 | $ 48,230 | 2.31 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 03 | view details |
TURN OFF EQUIPMENT WHEN NOT IN USE | 2.6218 | I | $ 1,300 | $ 35,170 | 0.04 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 04 | view details |
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | 2.4236 | I | $ 3,000 | $ 32,100 | 0.09 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 05 | view details |
USE SYNTHETIC LUBRICANT | 2.4314 | I | $ 0 | $ 6,890 | 0.00 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 06 | view details |
TURN OFF EQUIPMENT WHEN NOT IN USE | 2.6218 | N | $ 0 | $ 4,000 | 0.00 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 07 | view details |
INSTALL SKYLIGHTS | 2.7145 | N | $ 2,730 | $ 2,100 | 1.30 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 08 | view details |
UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | 2.7121 | I | $ 0 | $ 1,950 | 0.00 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 09 | view details |
TURN OFF EQUIPMENT WHEN NOT IN USE | 2.6218 | I | $ 0 | $ 1,780 | 0.00 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 10 | view details |
UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | 2.7142 | I | $ 380 | $ 1,385 | 0.27 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||