Industrial Assessment Centers
Assessment #AM0537
| Assessment Year | 2008 |
|---|---|
| SIC | 2096 |
| SIC Description | Potato Chips And Similar Snacks |
| NAICS | 311919 |
| NAICS Description | Other Snack Food Manufacturing |
| Principal Product | Snack foods |
| Sales | $ 337,000,000 |
| # of Employees | 500 |
| Plant Area (Sq.Ft.) | 330,000 |
| Annual Production | 108,000,000 Pounds |
| Production Hrs. Annual | 8,740 |
| Location (State) | TX |
| Yearly Energy Cost | $ 3,641,548 |
Current Energy Usage & Costs
| Energy Sources | Yearly Usage | Yearly Cost | Unit Price |
|---|---|---|---|
Electricity |
23,602,208 kWh | $ 1,310,445 | $ 0.056 /kWh |
- Demand Charge |
35,733 kW | $ 253,548 | $ 7.10 /kW |
- Electricity Fees |
- | $ 34,705 | - |
Natural Gas |
175,851 MMBtu | $ 1,728,587 | $ 9.83 /MMBtu |
Other Gas |
129,927 MMBtu | $ 314,263 | $ 2.42 /MMBtu |
TOTAL ENERGY |
547,701 MMBtu | $ 3,641,548 | $ 6.65 /MMBtu |
Recommended Reduction in Usage & Costs
|
Recommended Implemented |
| Energy Sources | Yearly Savings | Yearly Cost | % Saved | Unit Price |
|---|---|---|---|---|
Electricity |
4,335,570 kWh 3,940,070 kWh |
$ 328,340 $ 297,890 |
25.06 % 22.73 % |
$ 0.056 /kWh |
- Demand Charge |
6,590 kW 6,050 kW |
$ 44,855 $ 41,155 |
17.69 % 16.23 % |
$ 7.10 /kW |
- Electricity Fees |
- |
$ 0 $ 0 |
0.00 % 0.00 % |
- |
Natural Gas |
69,682 MMBtu 3,222 MMBtu |
$ 375,190 $ 16,890 |
21.71 % 0.98 % |
$ 9.83 /MMBtu |
Other Gas |
0 MMBtu 0 MMBtu |
$ 0 $ 0 |
0.00 % 0.00 % |
$ 2.42 /MMBtu |
TOTAL ENERGY |
114,122 MMBtu 43,608 MMBtu |
$ 748,385 $ 355,935 |
20.55 % 9.77 % |
$ 6.65 /MMBtu |
Recommendations
| AR # | Description | ARC Code | Status | Cost | Savings | Payback (Years) |
|||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | view details |
REPLACE BOILER | 2.1224 | N | $ 300,000 | $ 324,000 | 0.93 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 02 | view details |
USE MORE EFFICIENT LIGHT SOURCE | 2.7143 | I | $ 750,000 | $ 260,000 | 2.88 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 03 | view details |
ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | 2.4236 | I | $ 1,500 | $ 42,100 | 0.04 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 04 | view details |
ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | 2.1233 | N | $ 25,000 | $ 34,300 | 0.73 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 05 | view details |
UPGRADE CONVEYORS | 2.4325 | N | $ 80,000 | $ 34,150 | 2.34 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 06 | view details |
USE STEAM PRESSURE REDUCTION TO GENERATE POWER | 2.3321 | I | $ 59,850 | $ 18,255 | 3.28 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 07 | view details |
INSULATE BARE EQUIPMENT | 2.2511 | I | $ 12,000 | $ 15,000 | 0.80 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 08 | view details |
USE SYNTHETIC LUBRICANT | 2.4314 | I | $ 0 | $ 9,930 | 0.00 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 09 | view details |
USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | 2.4133 | I | $ 47,740 | $ 7,480 | 6.38 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 10 | view details |
USE MORE EFFICIENT LIGHT SOURCE | 2.7143 | I | $ 1,460 | $ 3,150 | 0.46 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 11 | view details |
REPAIR LEAKS IN LINES AND VALVES | 2.2133 | I | $ 500 | $ 1,890 | 0.26 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
| 12 | view details |
MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | 2.7124 | I | $ 0 | $ 750 | 0.00 | ||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||